Epson Stylus Pro GS6000
Revision F
TROUBLE SHOOTING
Remedies for Service Call Error
57
Confidential
1905
An abnormally low temperature of
the PRE HEATERS(64) on the
HEATER RELAY BOARD
ASSY
An abnormally low temperature of the PRE HEATERS(64) is detected.
Check whether the PRE HEATERS(64) are properly connected.
Check whether the THERMISTOR, PRE(s) is correctly installed.
Check whether the THERMISTOR, PRE(s) is properly connected.
Check whether the FUSE has blown. If so, replace the FUSE.
Replace the HEATER RELAY BOARD ASSY (
p.114
).
1906
An abnormally low temperature of
the PLATEN HEATER(64) on the
HEATER RELAY BOARD
ASSY
An abnormally low temperature of the PLATEN HEATER(64) is
detected.
Check whether the PLATEN HEATER(s)(64) is properly connected.
Check whether the THERMISTOR, PLATEN(s) is correctly installed.
Check whether the THERMISTOR, PLATEN(s) is properly connected.
Check whether the FUSE has blown. If so, replace the FUSE.
Replace the HEATER RELAY BOARD ASSY (
p.114
).
1907
An abnormally low temperature of
the AFTER HEATER(64) on the
HEATER RELAY BOARD
ASSY
An abnormally low temperature of the AFTER HEATER(64) is detected. Check whether the AFTER HEATER(s)(64) is properly connected.
Check whether the THERMISTOR, AFTER(s) is correctly installed.
Check whether the THERMISTOR, AFTER(s) is properly connected.
Check whether the FUSE has blown. If so, replace the FUSE.
Replace the HEATER RELAY BOARD ASSY (
p.114
).
1908
An abnormal voltage of the heater
on the HEATER CONT BOARD
ASSY
The voltage of the HEATER CONT BOARD ASSY is abnormally
changed.
Replace the HEATER CONT BOARD ASSY (
p.113
).
Replace the P/S BOARD ASSY (
p.117
).
1909
Serial communication failure
between the HEATER CONT
BOARD ASSY and SUB-B/C
BOARD
The serial communication between the HEATER CONT BOARD ASSY
and the SUB_B BOARD ASSY/SUB_C BOARD ASSY cannot be
made.
Check whether the serial cable is properly connected. If not, connect it
properly.
1910
Insufficient temperature of the
PRE HEATERS(64) on the
HEATER RELAY BOARD
ASSY
The required temperature of the PRE HEATERS(64) cannot be reached.
Check whether the AC cable for the heater is properly connected. If not,
connect the cable properly.
Check whether the THERMISTOR, PRE(s) is correctly installed.
Check whether the THERMISTOR, PRE(s) is properly connected.
Check whether the FUSE has blown. If so, replace the FUSE.
Replace the HEATER RELAY BOARD ASSY (
p.114
).
Error Code
Error Name
Description
Remedy/Point to be checked
Summary of Contents for Stylus Pro GS6000
Page 1: ...EpsonStylusProGS6000 Large Format Color Inkjet Printer SERVICE MANUAL SEIJ08001 Confidential ...
Page 11: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 40: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 49: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 63: ...Confidential C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 184: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 240: ...Confidential C H A P T E R 6 MAINTENANCE ...
Page 257: ...Confidential C H A P T E R 7 APPENDIX ...
Page 273: ...150 151 152 153 EPSON STYLUS PRO GS6000 No 06 Rev 01 CA01 CASE 061 ...
Page 277: ...Rev 01 CA01 MECH 031 No 10 EPSON STYLUS PRO GS6000 553 551 550 555 554 552 to SUB B J2 ...
Page 282: ...Rev 01 CA01 MECH 081 No 15 EPSON STYLUS PRO GS6000 702 702 702 701 700 703 704 704 703 702 ...
Page 288: ...FULL HOME Rev 01 CA01 MECH 151 No 22 EPSON STYLUS PRO GS6000 ...
Page 292: ...Rev 01 CA01 MECH 191 No 04 EPSON STYLUS PRO GS6000 to SUB C J5 867 ...
Page 296: ...Rev 01 CA01 MECH 231 No 30 EPSON STYLUS PRO GS6000 902 901 903 904 903 900 1 AKE UP T to ...