Chapter 1 Product Descriptions
Rev. A
1-9
1.2.9 Electrical Specifications
Table 1-7. Electrical Specification
Item
120V Version
220
∼
240V Version
Rated Voltage
120 VAC
220
∼
240 VAC
Input Voltage
Range
103.5
∼
132 V
198
∼
264 V
Rated Frequency
Range
50
∼
60 Hz
50
∼
60 Hz
Input Frequency
Range
49.5
∼
60.5 Hz
49.5
∼
60.5 Hz
Rated Current
0.5 A
(Max. 0.5 A)
0.3 A
(Max. 0.3 A)
Power
Consumption
Approx. 15 W
(ISO/IEC10561 LETTER pattern)
Approx. 15 W
(ISO/IEC10561 LETTER pattern)
Energy Star Compliant
Insulation
Resistance
10 M
Ω
, Min.
(applying 500 VDC between AC
line and chassis)
10 M
Ω
, Min.
(applying 500 VDC between AC
line and chassis)
Dielectric
Strength
AC 1000 Vrms for 1 min. or
AC 1200 Vrms for 1 sec.
(between AC line and chassis)
AC 1500 Vrms for 1 min.
(between AC line and chassis)
1.2.10 Environmental Conditions
Table 1-8. Environmental Conditions
Condition
Operating
Non operating
Temperature
10
∼
35
°
C
∗
3
-20
∼
60
°
C
∗
1
Humidity
20
∼
80 %
∗
2/3
5
∼
85 %
∗
1/2
Shock
Resistance
1G
(within 1 ms)
2G
(within 2 ms)
∗
1
Vibration
Resistance
0.15G
0.50G
∗
1
Note)
∗
1:
Applicable when the unit is in a shipping container.
∗
2:
Without condensation.
∗
3:
The unit should be operated within the range shown in figure below.
10
27
35
80
55
20
Humidity
(%)
Temperature
(°C)
Figure 1-5. Temperature and Humidity Range
Summary of Contents for Stylus Color 300
Page 1: ...EPSON TERMINAL PRINTER EPSON Stylus Color 300 SERVICE MANUAL EPSON 4007996 ...
Page 5: ...REVISION SHEET Revision Issued Contents A July 2 1997 First issue ...
Page 32: ...CHAPTER 5 TROUBLESHOOTING 5 1 OVERVIEW 5 1 5 1 1 Unit Repair C224 MAIN Board 5 1 ...
Page 36: ...CHAPTER 6 MAINTENANCE 6 1 OVERVIEW 6 1 6 1 1 Maintenance Request 6 1 ...
Page 38: ...APPENDIX A 1 OVERVIEW A 1 A 2 EEPROM Address Map A 2 A 3 CIRCUIT DIAGRAM C224 MAIN BOARD A 4 ...
Page 42: ...EPSON Stylus Color 300 Service Manual Rev A A 4 A 3 CIRCUIT DIAGRAM C224 MAIN BOARD ...
Page 44: ...EPSON SEIKO EPSON CORPORATION ...