SC-F9200 Series
Revision C
ADJUSTMENT
CR Related Adjustments
307
SE Group Confidential (Related Staff Only)
Figure 4-27. Placing the Thickness Gauge (left side)
6.
Measure the height of the CR Unit to see if it is within the standards.
(Measure at the both left and right of the CR Unit. Right and left set position refer
to
Within the standards: Cap the Print Head and end the adjustment.
Out of the standards: Go to
7.
Move the CR Unit to the left end, and remove the CR Cover.
8.
Loosen the screws that secure the left and right PG adjustment levers.
9.
Move the PG adjustment levers up and down to change the gap (PG).
10. Tighten the screws to secure the PG adjustment levers, and go back to
, and
repeat the procedure until the height of the CR Unit falls inside the standard range.
Figure 4-28. PG Adjustment Levers
Left side of Head
Upper
Print Head 1
Thickness gauge
Thickness gauge
Print Head 1
Front
Print Head 2
Metal pointer
Metal pointer
Set the thickness gauge aligning the top
edge with the upper edge of the suction
holes.
Suction hole
Thickness gauge
Thickness gauge
Metal pointer
Place the thickness gauge while aligning
the left end of the gauge with the metal
pointer.
PG Adjustment Levers
Raise the lever to move the CR up
Lower the lever to move the CR down
Fixing screws
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...