6 PRECAUTIONS
■
Function differences
<SVD circuit>
• The SVD function is implemented by varying the apparent power supply voltage with the SVDT
control.
• The SVD response time is different from the actual IC. It is necessary to take an appropriate waiting
time for getting the SVD result.
<Oscillation circuit>
• For OSC1, 32.768 kHz or 38.4 kHz crystal oscillation can be selected.
The OSC3 oscillation frequency is fixed at 1 MHz when ceramic oscillation is used. When CR oscilla-
tion is used, the frequency can be adjusted approximately from 50 kHz to 1400 kHz using the OSC3CR
control mounted on the board.
Either OSC1 or OSC3 can be selected as the system clock.
• The oscillation stabilization time for OSC3 and OSC1 is shorter than the actual IC. The time from
turning the OSC3 oscillation on to switching the system clock to OSC3 should be secured according to
the time of the actual IC.
• Use separate instructions for turning the OSC3 oscillation on and for switching the clock from OSC1
to OSC3. The same applies when turning the OSC1 oscillation off after switching the clock from OSC3
to OSC1. The S5U1C60N15E may operate if this processing is performed at the same time. Be sure to
use separate instructions according to the actual IC when creating the program.
• The oscillation start and stop times are different from those of the actual IC, because the logic level of
the S5U1C60N15E is higher than that of the actual IC.
<Undefined data memory area>
In the S5U1C60N15E, values that are read from unmapped memory areas will be undefined. How-
ever, the undefined status differs from the actual IC, therefore pay attention to the memory area when