S5U1C17001C ManUal
EPSOn
10-173
(C COMPilEr PaCkagE fOr S1C17 faMily) (Ver. 1.5.0)
10 DEBUggEr
10
Debugger
10.11.7 ES-Sim17 Error Massages
Table 10.11.7.1 Error messages (displayed in the
gdb
[Console] window)
Message
Description
ES-Sim error 01 : Loading the dll file was failed.
The dll file for
ES-Sim17
does not exist in the default location or
cannot be loaded normally.
ES-Sim error 02 : Opening the CPU construction file
was failed.
The CPU configuration file does not exist in the specified
location or cannot be loaded normally.
ES-Sim error 03 : Generating the CPU components
was failed.
The
ES-Sim17
has failed generation of the CPU module as the
CPU module definition is incorrect or no required dll file exists.
ES-Sim error 04 : Connecting the CPU components
was failed.
The
ES-Sim17
has failed correction to the CPU module
generation as the connect destination in the CPU module
definition is incorrect.
ES-Sim error 05 : Opening the "user.ini" was failed. The user setting file does not exist in the specified location or
cannot be opened normally.
ES-Sim error 06 : Setting of the "user.ini" is invalid. The setting value written in the user setting file is incorrect.
Table 10.11.7.2 Error messages (displayed in a dialog box)
Message
Description
Failed to save "
path
\
file
".
The
ES-Sim17
has failed saving the captured image to the file.
Failed to open “path\file”.
Please confirm the file is fitting with the CPU type,
or the file is existing.
The Lcd file could not be opened.
10.11.8 restrictions
•
The
ES-Sim17
supports the model shown below.
S1C17701
、
S1C17702
、
S1C17704
、
S1C17602
、
S1C17001
•
The ES-Slim17 supports monochrome dot-matrix LCD and monochrome segment LCD panels as external
devices.
•
The dot size, contrast, and panel color of the LCD window are different from those of the actual LCD panels.
•
The
ES-Sim17
performs simulation on an instruction cycle basis. Therefore, operation cycles lower than the
instruction cycle cannot be simulated.
•
The
ES-Sim17
simulates the operation clock based on the instruction cycles. Therefore, the operation timings are
not the same as those of the actual hardware.
•
The functions listed below cannot be simulated.
1. Timer clock and oscillation clock external outputs
2. Data transfer using the UART, I
2
C and SPI
3. Noise and chattering filters
•
More than one
ES-Sim17
cannot be run on a PC for simulation.
•
Setting higher oscillation clock frequency causes degradation of simulation performance.
•
The I/O control registers that are not supported by the
ES-Sim17
function as general-purpose read/write registers.
Also they are not initialized at a reset.
•
Some peripheral circuits, such as the oscillator and SVD circuits, need time until their operations stabilize. In the
simulation by the
ES-Sim17
, they can operate with stability immediately after they start.
*
For the restrictions in the latest version of
ES-Sim17
and model dependent restrictions, refer to "simulator_
readme.txt".
Summary of Contents for S5U1C17001C
Page 6: ......
Page 17: ...1 General S5U1C17001C Manual 1 General ...
Page 18: ......
Page 21: ...1 2 Install S5U1C17001C Manual 2 Installation ...
Page 22: ......
Page 29: ...3 SoftDev S5U1C17001C Manual 3 Software Development Procedures ...
Page 30: ......
Page 103: ...4 SrcFiles S5U1C17001C Manual 4 Source files ...
Page 104: ......
Page 121: ...5 IDE S5U1C17001C Manual 5 gnU17 iDE ...
Page 122: ......
Page 365: ...6 Compiler S5U1C17001C Manual 6 C Compiler ...
Page 366: ......
Page 385: ...7 Library S5U1C17001C Manual 7 library ...
Page 386: ......
Page 405: ...8 Assemblr S5U1C17001C Manual 8 assembler ...
Page 406: ......
Page 439: ...9 Linker S5U1C17001C Manual 9 linker ...
Page 440: ......
Page 449: ...10 Debugger S5U1C17001C Manual 10 Debugger ...
Page 450: ......
Page 626: ...11 Tools S5U1C17001C Manual 11 Other Tools ...
Page 627: ......
Page 696: ...S1C17 Family C Compiler Package Quick Reference Reference ...