6. SPECIFICATIONS
S1S65010
EPSON
25
Evaluation Board Technical Manual (Rev. 1.1e)
<LAN debugging>
Debugging of the reference code is also possible over a LAN cable connected to a PC. Note, however,
that a direct connection to a PC requires a cross cable.
The following is the procedure.
1. Connect the two boards (main and camera).
2. Connect the power supply to the power supply connector.
3. Turn on the green power supply LED on the board to light.
4. Connect the kit to the PC with an Ethernet cross cable or to a hub with a straight cable.
5. Change the PC’s IP address to match the target.
This evaluation board set the default IP address 192.168.1.253, so make sure that there are no
duplications of IP addresses.
We recommend the following Japanese free software for changing the PC’s IP address.
Win95 Series:
KemaNet
http://www.vector.co.jp/soft/win95/net/se060975.html
Win2K Series:
valhell IP config
http://www.vector.co.jp/soft/winnt/net/se132582.html
6. Test the cable connection and IP address setting with the following console command.
ping 192.168.1.253
If everything is functioning correctly, there should be a response similar to the following.
------------------------------------------------
Pinging 192.168.1.253 with 32 bytes of data:
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Ping statistics for 192.168.1.253:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
------------------------------------------------
7. Boot the PC’s Web browser (Internet Explorer, Netscape, etc.)
If the Java plug-in has not been installed, download it from the following URL.
http://java.sun.com/getjava/ja/install-windows.html
8. Access the following address with the Web browser.
http://192.168.1.253/
9. Click on “
Continuous image
” on the menu screen that appears.
10. Input the user name and password, then start capturing/monitoring. This board ships with only one
user and the following default password.
User name: root
password: administrator
Summary of Contents for S1S65010
Page 3: ......
Page 5: ......
Page 37: ...9 MISCELLANEOUS 30 EPSON S1S65010 Evaluation Board Technical Manual Rev 1 1e ...