PhotoPC700
Chapter5 Adjustment
Rev. A
5-8
2. Following screen appears.
Button for Flange-back Adjustment
Figure 5-6. Button Location for Flange-Back Adjustment
3. Project a Siemens star chart, which is attached in the end of the manual book, at a distance of
69cm
±
3cm in front of the camera lens.
4. Press “Focus” button on the screen.
5. Since the screen to confirm the selection appears, press Y(Yes).
Be sure that adjustment
value is within 34 to 60.
Figure 5-7.Screen to confirm the Result After Adjustment
6. The camera shoots one time automatically and Flange-back adjustment value appears on the
screen.
7. Be sure that adjustment value appeared on the screen(45 in the example above) is within the
range 34 to 60.
Flange-back (Focus) adjustment value = 34
∼
60
CAUTION
If the value is not within the range above, adjust it again. Also, if re-
adjusted value is not within the rage again, exchange CA1, CA2 boards
or CCD.