L350/L300/L355/L210/L110 Series
Revision B
Confidential
Maintenance
Lubrication Points and Instructions
69
Figure 4-15. Lubrication of the Scanner Carriage (1)
<Part supply as ASP>
Supplied as the Scanner
Unit
<Lubrication status when
supplied as ASP>
Lubricated
<Lubrication Point>
Contact points (x6) on the
Scanner Carriage with the
CIS Module Unit
<Type>
G-74
<Application Amount>
Appropriate amount
<Remarks>
Apply with flux
dispenser.
Stir G-74 before use.
For section A, apply
grease over the area
shown in the Cross-
section view.
Section A (See Cross-section view.)
Section A (See Cross-section view.)
Cross-section of section A
Scanner Carriage
CIS Module Unit
Application Point
Figure 4-16. Lubrication of the Scanner Carriage (2)
<Part supply as ASP>
Supplied as the Scanner
Unit
<Lubrication status when
supplied as ASP>
Lubricated
<Lubrication Point>
On inner wall surfaces (x4)
on the groove of the
Scanner Carriage
<Type>
G-45
<Application Amount>
0.01 g x 4 points
<Remarks>
Using injector, apply
grease on inner wall
surfaces (x4) on the
groove shown in the
enlarged figure.
Be careful not to let
grease flow over.
Scanner Carriage
Enlarged figure
Apply on the
center of inner
wall (x4 points).
Application Point
Figure 4-17. Lubrication of the Panel Stand
<Part supply as ASP>
Supplied as the Panel Unit
<Lubrication status when
supplied as ASP>
Lubricated
<Lubrication Point>
Shafts (x4) of the Panel
Stand
<Type>
G-74
<Application Amount>
Appropriate amount
<Remarks>
Using flux dispenser,
apply all over the shafts
shown in the figure.
Stir G-74 before use.
Panel Stand
Application Point