Expression 10000XL
Revision A
DISASSEMBLY/ASSEMBLY
Disassembly Procedure
52
4.2.12 Disassembly of TPU
4.2.12.1 Removal of TPU Lower Housing
1. Release the TPU Carriage lock.
Figure 4-36. Release of TPU Carriage Lock
2. Remove the eight screws (CB SCREW, M3x6:4 pcs, CBP, M3x10:4 pcs) that are
securing the TPU Lower Housing.
3. Lift and remove the TPU Lower Housing.
Figure 4-37. Removal of TPU Lower Housing
After reinstalling the TPU Lower Housing, be sure to lock the TPU
Carriage Lock.
Locking position
Unlocking position
TPU Carriage Lock
M3x10
(50±10Ncm)
M3x6
(50±10Ncm)
TPU Lower Housing
Summary of Contents for Expression 10000XL Series
Page 1: ...EPSON Expression10000XL Color Flatbed Scanner SERVICE MANUAL IMAGE SESC04 001 ...
Page 5: ...Revision Status Revision Date of Issue Description A May 14 2004 First Release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 20: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 25: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 32: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 64: ...C H A P T E R 5 ADJUSTMENT ...
Page 67: ...C H A P T E R 6 MAINTENANCE ...
Page 70: ...C H A P T E R 7 APPENDIX ...
Page 74: ...Main Board 1 ...
Page 75: ...Main Board 2 ...
Page 76: ...Main Board 3 ...
Page 77: ...SUB Board ...
Page 78: ...Power Supply Board ...
Page 79: ...Inverter Board ...
Page 80: ...CCD Sensor Board ...
Page 81: ...Panel Board ...
Page 82: ...TPU Main Board ...
Page 86: ...27 14 79 83 10 78 67 67 Rev 01 B168 MECH 0011 ES 10000G Expression 10000XL No 3 ...