4.2.3 Removal of Housing Upper
1. Remove the Document Cover.
(Refer to 4.2.1 Removal of Document Cover)
2. Insert a flat-blade screwdriver into the notch of the Screw Protector, and remove the
Screw Protector (4 pcs.) from the Housing Upper.
3. Remove the five screws (CBP, M4 x 12: 4 pcs., M3 x 4: 1 pc.) that are securing the
Housing Upper.
Figure 4-5. Removal of Screws and Screw Protectors
4. Lift and remove the Housing Upper.
Figure 4-6. Removal of Housing Upper
Location of M4x12 (70±10Ncm)
Screw Protectors
Screw Protectors
Housing Upper
M3x4
(70±10Ncm)
When reinstalling the Screw Protector, push it until it clicks.
Summary of Contents for Expression 10000XL Series
Page 1: ...EPSON Expression10000XL Color Flatbed Scanner SERVICE MANUAL IMAGE SESC04 001 ...
Page 5: ...Revision Status Revision Date of Issue Description A May 14 2004 First Release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 20: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 25: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 32: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 64: ...C H A P T E R 5 ADJUSTMENT ...
Page 67: ...C H A P T E R 6 MAINTENANCE ...
Page 70: ...C H A P T E R 7 APPENDIX ...
Page 74: ...Main Board 1 ...
Page 75: ...Main Board 2 ...
Page 76: ...Main Board 3 ...
Page 77: ...SUB Board ...
Page 78: ...Power Supply Board ...
Page 79: ...Inverter Board ...
Page 80: ...CCD Sensor Board ...
Page 81: ...Panel Board ...
Page 82: ...TPU Main Board ...
Page 86: ...27 14 79 83 10 78 67 67 Rev 01 B168 MECH 0011 ES 10000G Expression 10000XL No 3 ...