background image

ISSUED: 01-23-07  SHEET #:055-9498-2 05-29-08

5 of 10

Visit  the  Peerless  Web  Site  at  www.peerlessmounts.com

For Technical Support Contact Peerless Mounts at 1-800-729-0307 or 708-865-8870.

F

G

WOOD
JOIST

CEILING

Drill two 5/32" (4 mm) dia. holes to a minimum depth
of 2.5" (64 mm). Attach ceiling plate (

G

) with two

#14 x 2.5" (6 mm x 65 mm) wood screws (

F

) as

shown using 3/8" (10 mm) socket wrench.

Skip to step 2.

For optional Cord Management,

install two spacers (

H

) between ceiling

plate (

G

) and ceiling.

Installation To Wood Joist Ceilings

WOOD
JOIST

CEILING

F

G

H

H

• Tighten wood screws (

F

) so that wall plate (

G

) is firmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in • lb (9 N.M.).

• Make sure that mounting screws are anchored into the

center of the studs. The use of an "edge to edge" stud
finder is highly recommended.

WARNING

• It is the responsibility of the installer to verify that the

supporting surface will safely support the combined
load of all attached hardware and components.

WARNING

1

IMPORTANT: Be sure to drill holes into the joist CENTER!

Summary of Contents for ELPMBPJF

Page 1: ...F 3215 W North Ave Melrose Park IL 60160 800 865 2112 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com Maximum UL Load Capacity 50 lb 22 7 kg This product is UL Listed It must be installed by a qualified professional installer R Manufactured by Peerless Industries Inc ...

Page 2: ...ructions or warnings call Peerless customer care at 1 800 729 0307 This product should only be installed by someone of good mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load...

Page 3: ...ead socket pin screw 1 520 2151 F 14 x 2 5 phillips hex head wood screw 2 5S1 015 C04 G ceiling plate 1 580 4042 H 25 ID x 56 OD x 26 spacer 2 590 2071 I extension column connector with cord management 1 580 4025 J 10 32 x 3 8 socket pin screw 2 520 2084 K 10 32 x 3 16 slotted set screw 3 520 2187 L adapter plate 1 055 KUNV S 2 M M3 x 8 mm serrated washer head socket pin screw 4 510 2004 N M4 x 10...

Page 4: ... wrench B See detail 2 Screw projector mount A into extension column connector I Align slot in projector mount A to one of the bottom holes in extension column connector I Insert and tighten one 10 32 x 3 8 socket pin screw J through extension column connector into slot in projector mount A using security allen wrench B See detail 3 NOTE Slotted set screws K are used to jam against the threads of ...

Page 5: ...iling plate G and ceiling Installation To Wood Joist Ceilings WOOD JOIST CEILING F G H H Tighten wood screws F so that wall plate G is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that mounting screws are anchored into the center of the studs The use of an edge to edge stud finde...

Page 6: ...ceilings covered with a layer of plaster drywall or other finishing material If mounting to concrete ceiling covered with plaster drywall is unavoidable plaster drywall must be counterbored as shown below WARNING 1 CUTAWAY VIEW INCORRECT concrete metal bracket plaster dry wall CORRECT concrete metal bracket plaster dry wall Illustration A F G CONCRETECEILING CONCRETE ANCHOR Tighten wood screws so ...

Page 7: ...w NOTE Some projectors may have three or four attachment points If projector has three attachment points the unused leg may be removed Place projector upside down Locate adapter plate L with notch facing forward as close to projector center of gravity as possible without covering any mounting holes Loosen channels and if there are only three mounting holes remove fourth channel Using one channel f...

Page 8: ...hannel FOOT OF CHANNEL L M N O or P 4 Attach projector with adapter plate already on it to the projector mount A by inserting the projector mount A into the adapter plate connection and twisting until the adapter plate will no longer turn about 75 The spring loaded captive screw should line up with a corresponding hole on the adapter plate this should line up automatically when the two are connect...

Page 9: ...son www epson com ELPMBC01 Adjustable Extension Column Pipe 8 11 8 11 adjustable extension in 1 increments Specially designed to allow internal cable management 1 11 5 NPT pipe threaded on both ends Notched ends for use with set screw to provide safety and security Color White ELPMBP01 Adjustable Suspended Ceiling Channel Kit Mounts above 2 x 2 or 2 x 4 ceiling tile to structural ceiling with tie ...

Page 10: ... LV QRW DXWKRUL HG IRU VXFK VHUYLFH RU UHSDLUV E 3HHUOHVV QGXVWULHV QF E WKH IDLOXUH WR XWLOL H SURSHU SDFNLQJ ZKHQ UHWXUQLQJ WKH SURGXFW F LQFRUUHFW LQVWDOODWLRQ RU WKH IDLOXUH WR IROORZ 3HHUOHVVҋ LQVWUXFWLRQV RU ZDUQLQJV ZKHQ LQVWDOOLQJ XVLQJ RU VWRULQJ WKH SURGXFW RU G PLVXVH RU DFFLGHQW LQ WUDQVLW RU RWKHUZLVH LQFOXGLQJ LQ FDVHV RI WKLUG SDUW DFWLRQV DQG IRUFH PDMHXUH Q QR HYHQW VKDOO 3HHUOHVV...