EH-TW3500/4500/5500
Disassembly and Assembly
CONFIDENTIAL
SEIKO EPSON
98
Revision A
2.
Ground continuity check
Testing apparatus
Multimeter (with sensitivity down to 0.1
Ω
)
Standard/Judgment level
Should be no resistance (0.5
Ω
or less)
Testing procedure
1.
Insulation resistance test
1. Turn on the power switch.
2. Set the range selection switch to
Ω
.
3. Connect the black lead wire to the COM terminal.
4. Connect the red lead wire to the V/
Ω
/Hz terminal.
5. Check that the resistance at (1) in the diagram below is 0.5
Ω
or less.
Figure 3-43.
2.
Illumination check
•
Test conditions: Input a PC or video signal to the LCP and check the
illumination for about 5 minutes.
•
Judgment
:
Projector should operate normally with no smoke or
fire.
Display
MEASURE SW
DC/AC, SW
Range selection switch
Terminals
V, ɹ, Hz
COM
Power supply lines
Exposed metal part of projector
PC connector
Projector AC inlet
Summary of Contents for DREAMIO EH-TW2900
Page 1: ...EH TW2900 3500 4400 4500 5500 Multimedia Projector SERVICE MANUAL CONFIDENTIAL ...
Page 9: ...CONFIDENTIAL C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 16: ...CONFIDENTIAL C H A P T E R 2 TROUBLESHOOTING ...
Page 46: ...CONFIDENTIAL C H A P T E R 3 DISASSEMBLYANDASSEMBLY ...