EPSON AcuLaser C8500
Revision C
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
3-71
3.2.12.2 MAIN FUSER ASSY (PL9.1.2) Removal
1.
Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2.
Pull out the FUSER ASSY.
3.
Disconnect the 2 connectors (P/J72B, P/J79) of the MAIN FUSER ASSY.
4.
Remove the 3 screws (gold, w/washer, 8mm) securing the MAIN FUSER
ASSY, Remove the MAIN FUSER ASSY.
Figure 3-79. MAIN FUSER ASSY Removal
C A U T I O N
After replacing the MAIN FUSER ASSY with a new part,
enter the maintenance mode to reset the counter (Fuser
Counter Clear). (For details, see Chapter 6.)
When installing the MAIN FUSER ASSY, make sure to set it
from directly above. If not, the earth spring will be
exposed, and it can cause paper jam.
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......