Assembly Notes
Mount the
PW sensor assembly
onto the ribbon mask holder groove, aligning the bottom line of micro
photo sensor to the bottom line of the groove.
Whenever you remove the PW sensor assembly, clean the surface of the sensor by wiping it with a
soft material. If the surface is not clean, abnormal operations may occur, such as printing on the
platen surface.
The tightening torque for the CB screw (2.5
×
5, F/Zn) =
0.08 ~ 0.12 Nm (0.8 ~ 0.12 Kg f-cm)
When you replace the PW sensor assembly, reset the TPE level. Refer to Chapter 4.
CB Screw ( 2.5X5 F/Zn)
PW Sensor Assembly
Ribbon Mask Holder
View of PW Sensor
through Ribbon Mask Holder
Bold Perforated line is the Groove.
Micro Photo Sensor
Figure 3-10 Mounting Position for the PW Sensor Assembly
LQ-2070 Service Manual
Disassembly and Assembly
Rev.A
3-9
Summary of Contents for 2070 - LQ B/W Dot-matrix Printer
Page 1: ...EPSON TERMINAL PRINTER LQ 2070 SERVICE MANUAL EPSON 4006244 ...
Page 5: ...REVISION SHEET Revision Issued Date Revision Page Rev A April 8 1996 1st issued ...
Page 11: ...Product Description LQ 2070 Service Manual Figure 1 1 Exterior View of the LQ 2070 1 2 Rev A ...
Page 55: ...LQ 2070 Service Manual Operating Principles Rev A 2 7 ...
Page 58: ...Operation Principles LQ 2070 Servcie Manual 2 10 Rev A ...
Page 63: ...Down LQ 2070 Service Manual Operating Principles Rev A 2 15 ...
Page 112: ...Disassembly and Assembly LQ 2070 Service Manual 3 34 Rev A ...
Page 146: ...Maintenance LQ 2070 Service Manual 6 4 Rev A ...
Page 165: ...EPSON ...