4
IMPORTANT SAFETY INSTRUCTIONS
WARNING
– TO REDUCE THE RISK OF INJURY OR DEATH:
1.
READ AND FOLLOW ALL INSTRUCTIONS.
2.
NEVER LET CHILDREN OPERATE OR PLAY WITH GATE CONTROLS.
3.
Always keep people and objects away from the gate. NO ONE SHOULD
CROSS THE PATH OF THE MOVING GATE.
4.
Test the gate operator monthly. The gate MUST reverse on contact
with a rigid object or stop when an object activates a non-contact
sensor. After adjusting the force or the limit travel, retest the gate
operator. Failure to adjust and retest the gate operator properly can
increase the risk of injury or death.
5.
MAKE SURE THERE IS AT LEAST 16" CLEARANCE BETWEEN THE
GATE ARM AND ANY RIGID OBJECTS SUCH AS A WALL.
6.
Install a minimum of 2 warning signs in the area of the gate. Each
warning sign shall be visible by persons located on each side of the
gate. The warning signs shall indicate the following:
· The gate is automatic and could move at any time, posing a serious
risk of entrapment.
· Children should not be allowed to operate the gate or play in the gate
area.
· The gate should be operated only when it is visible to the operator
and only when the area is free of people and obstructions.
· The entrance is for vehicles only. Pedestrians must use separate
entrance.
7.
KEEP GATES PROPERLY MAINTAINED. Read the owner's manual.
Have a qualified service person make repairs to the gate hardware.
8.
SAVE THESE INSTRUCTIONS.
WARNING
– TO REDUCE THE RISK OF INJURY TO
PERSONS, USE THE OPERATOR ONLY WITH
INTENDED LENGTH OF GATE ARM
MODEL 301-10 = 10 FOOT WOODEN GATE ARM
MODEL 301-12 = 12 FOOT WOODEN GATE ARM
MODEL 301-14 = 14 FOOT WOODEN GATE ARM
MODEL 301-16 = 16 FOOT WOODEN GATE ARM
OPERATING INSTRUCTIONS
DO NOT INSTALL GATE ARM UNTIL GATE HAS BEEN TESTED FOR PROPER
OPERATION
TO PUT THE GATE INTO OPERATION:
Check all field wiring connections per the applicable drawing. Turn the circuit breaker on. The gate is
now ready for normal cycling operation. If it becomes necessary to remove the gate from service, turn
the circuit breaker off.
TO OPEN THE GATE IN AN EMERGENCY:
Put RAISE/LOWER switch to RAISE position. After the gate is opened, turn the circuit breaker off. The
gate arm will not lower with the circuit breaker in this position.
TO OPERATE THE GATE DURING POWER FAILURE:
Open door and switch circuit breaker OFF. Rotate the speed reducer pulley by hand until the gate arm
is in the desired position.