29
Instruction Manual
PS 8000 DT Series
EN
Date: 03-05-2016
About the device
PS 8160-04 DT
PS 8080-40 DT
PS 8360-10 DT
PS 8080-60 DT
PS 8360-15 DT
Mains input
Input voltage
90…264V AC
90…264V AC
90…264V AC
90…264V AC
90…264V AC
Input voltage with derating
-
-
-
90...150V
90...150V
Input current at 230V
max. 3.2A
max. 4.8A
max. 7.5A
max. 7.5A
max. 7.5A
Input current at 100V
max. 7.5A
max. 11.4A
max. 11.4A
max. 11.4A
max. 11.4A
Input frequency
45…65Hz
45…65Hz
45…65Hz
45…65Hz
45…65Hz
Input fuse
T 8A
T 16A
T 16A
T 16A
T 16A
Power factor
> 0.99
> 0.99
> 0.99
> 0.99
> 0.99
Output - Voltage
Nominal voltage U
Nom
160V
80V
360V
80V
360V
Adjustable range
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.02%
< 0.02%
< 0.02%
< 0.02%
< 0.02%
Stability at 10…90% load
< 0.05%
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Transient recovery time 10….90% load
< 2ms
< 2ms
< 2ms
< 2ms
< 2ms
Ripple LF BWL 300kHz
< 20mV RMS
< 4mV RMS
< 11mV RMS
< 4mV RMS
< 8mV RMS
Ripple HF BWL 20MHz
< 120mV P-P
< 10mV P-P
< 30mV P-P
< 10mV P-P
< 50mV P-P
Accuracy*
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
100mV
10mV
100mV
10mV
100mV
Remote sense compensation
max. 2V
max. 2,5V
max. 8V
max. 2,5V
max. 8V
Overvoltage protection
threshold (adjustable)
0…176V
0….88V
0…396V
0….88V
0…396V
Output - Current
Nominal current I
Nom
4A
40A
10A
60A
15A
Adjustable range
0A…I
Nom
0A…I
Nom
0A…I
Nom
0A…I
Nom
0A…I
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.05%
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Stability at 0…100%
∆
U
OUT
< 0.15%
< 0.15%
< 0.15%
< 0.15%
< 0.15%
Ripple HF BWL 20MHz
< 3mA P-P
< 19mA P-P
< 1mA P-P
< 19mA P-P
< 1mA P-P
Accuracy*
≤
0.7%
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
1mA
10mA
10mA
10mA
10mA
Output - Power
Nominal power P
Nom
640W
1000W
1000W
1500W
1500W
Nominal power at derating
-
-
-
1000W
1000W
Adjustable range
-
0...P
Nom
0...P
Nom
0...P
Nom
0...P
Nom
Accuracy*
-
≤
1%
≤
1%
≤
1%
≤
1%
Resolution of adjustment
-
1W
1W
1W
1W
Efficiency
≤
92%
≤
93%
≤
92%
≤
93%
≤
93%
Miscellaneous
Cooling
by fan
by fan
by fan
by fan
by fan
Ambient temperature
0….50°C
0….50°C
0….50°C
0….50°C
0….50°C
Storage temperature
-20….70°C
-20….70°C
-20….70°C
-20….70°C
-20….70°C
Humidity rel.
< 80%
< 80%
< 80%
< 80%
< 80%
Dimensions (WxHxD)
330x118x308mm
330x118x388mm
330x118x388mm
330x118x388mm
330x118x388mm
Weight
6,5kg
8,5kg
8,5kg
8,5kg
8,5kg
Sharebus for parallel connection
no
yes
yes
yes
yes
Isolation of input to output
2500V DC
2500V DC
2500V DC
2500V DC
2500V DC
Isolation of output to PE
1500V DC
950V DC
2100V DC
950V DC
2100V DC
Isolation of -output to PE
Series connection
Parallel connection
Humidity
Safety
EMC standards
Overvoltage class
Protection class
Analogue programming
Voltage range
Accuracy set/actual values
Input impedance
Article number
09200135
09200136
09200138
09200137
09200139
300V DC
≤
0.2%
<80%
possible, up to max. 600V total voltage
possible, max. 30 units, models from 1000W via Share bus
approx. 53k
Ω
0…5V or 0…10V (selectable)
Class I
EN 60950
EN 61326, EN 55022 Class B
Class II
* Related to the nominal value, the accuracy defines the maximum allowed deviation between set value and actual value.
Example: a 65 V model has min. 0.2% voltage accuracy. This is 130 mV. When setting a voltage of 5 V and with an allowed maximum deviation of 130 mV, the resulting
actual value could be between 4.87 V and 5.13 V.