28
EN
Instruction Manual
PS 8000 DT Series
Date: 03-05-2016
About the device
2.2 Technical specifications
PS 8016-20 DT
PS 8032-10 DT
PS 8065-05 DT
PS 8032-20 DT
PS 8065-10 DT
Mains input
Input voltage
90…264V AC
90…264V AC
90…264V AC
90…264V AC
90…264V AC
Input voltage with derating
-
-
-
-
-
Input current at 230V
max. 1.8A
max. 1.8A
max. 1.8A
max. 3.2A
max. 3.4A
Input current at 100V
max. 3.8A
max. 3.8A
max. 3.8A
max. 7.5A
max. 7.5A
Input frequency
45…65Hz
45…65Hz
45…65Hz
45…65Hz
45…65Hz
Input fuse
T 8A
T 8A
T 8A
T 8A
T 8A
Power factor
> 0.99
> 0.99
> 0.99
> 0.99
> 0.99
Output - Voltage
Nominal voltage U
Nom
16V
32V
65V
32V
65V
Adjustable range
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.02%
< 0.02%
< 0.02%
< 0.02%
< 0.02%
Stability at 10…90% load
< 0.05%
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Transient recovery time 10….90% load
< 2ms
< 2ms
< 2ms
< 2ms
< 2ms
Ripple LF BWL 300kHz
< 4mV RMS
< 10mV RMS
< 20mV RMS
< 8mV RMS
< 10mV RMS
Ripple HF BWL 20MHz
< 40mV P-P
< 100mV P-P
< 150mV P-P
< 100mV P-P
< 150mV P-P
Accuracy*
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
10mV
10mV
10mV
10mV
10mV
Remote sense compensation
max. 2V
max. 2V
max. 2V
max. 2V
max. 2V
Overvoltage protection
threshold (adjustable)
0…17.6V
0…35.2V
0…71.5V
0…35.2V
0…71.5V
Output - Current
Nominal current I
Nom
20A
10A
5A
20A
10A
Adjustable range
0A…I
Nom
0A…I
Nom
0A…I
Nom
0A…I
Nom
0A…I
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.05%
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Stability at 0…100%
∆
U
OUT
< 0.15%
< 0.15%
< 0.15%
< 0.15%
< 0.15%
Ripple HF BWL 20MHz
< 60mA P-P
< 35mA P-P
< 12mA P-P
< 65mA P-P
< 25mA P-P
Accuracy*
≤
0.7%
≤
0.7%
≤
0.7%
≤
0.7%
≤
0.7%
Resolution of display
10mA
10mA
1mA
10mA
10mA
Output - Power
Nominal power P
Nom
320W
320W
325W
640W
650W
Nominal power at derating
-
-
-
-
-
Adjustable range
-
-
-
-
-
Accuracy*
-
-
-
-
-
Resolution of adjustment
-
-
-
-
-
Efficiency
≤
90.5%
≤
89%
≤
93%
≤
90.5%
≤
91%
Miscellaneous
Cooling
by fan
by fan
by fan
by fan
by fan
Ambient temperature
0….50°C
0….50°C
0….50°C
0….50°C
0….50°C
Storage temperature
-20….70°C
-20….70°C
-20….70°C
-20….70°C
-20….70°C
Humidity rel.
< 80%
< 80%
< 80%
< 80%
< 80%
Dimensions (WxHxD)
330x118x308mm
330x118x308mm
330x118x308mm
330x118x308mm
330x118x308mm
Weight
6,5kg
6,5kg
6,5kg
6,5kg
6,5kg
Sharebus for parallel connection
no
no
no
no
no
Isolation of input to output
2500V DC
2500V DC
2500V DC
2500V DC
2500V DC
Isolation of +output to PE
500V DC
500V DC
700V DC
500V DC
700V DC
Isolation of -output to PE
Series connection
Parallel connection
Humidity
Safety
EMC standards
Overvoltage class
Protection class
Analogue programming
Voltage range
Accuracy set/actual values
Input impedance
Article number
09200130
09200131
09200132
09200133
09200134
300V DC
≤
0.2%
<80%
possible, up to max. 600V total voltage
possible, max. 30 units, models from 1000W via Share bus
approx. 53k
Ω
0…5V or 0…10V (selectable)
Class I
EN 60950
EN 61326, EN 55022 Class B
Class II
* Related to the nominal value, the accuracy defines the maximum allowed deviation between set value and actual value.
Example: a 65 V model has min. 0.2% voltage accuracy. This is 130 mV. When setting a voltage of 5 V and with an allowed maximum deviation of 130 mV, the resulting
actual value could be between 4.87 V and 5.13 V.