background image

EasyMax L Self-Monitoring Blood Glucose System

Training Information 

for 

Healthcare Professionals

Page 11

Summary of Contents for EasyMax L

Page 1: ...ng Blood Glucose System This Manual is intended for facilities where point of care testing is conducted by a healthcare professional Please thoroughly read the EasyMax L Owner s Guide and all product...

Page 2: ...ctured by EPS Bio Technology Corp No 8 R D Road III Hsinchu Science Park Hsinchu Taiwan 30077 Customer Service 1 866 994 3345 Toll Free Mon Fri 9 00 AM 9 00 PM EasyMax L Self Monitoring Blood Glucose...

Page 3: ...from your fingertip and forearm The meter is for outside the body in vitro use It should not be used to diagnose diabetes EasyMax L blood glucose meter can only be used with EasyMax Blood Glucose Tes...

Page 4: ...9 3 8 Alternate Site Testing AST EasyMax L gives patients the option to test on their fingertip or forearm Blood glucose test results obtained from the forearm may differ significantly from fingertip...

Page 5: ...040 F 100 C 400 C Relative Humidity R H 90 Blood Sample 0 6 L Fresh Blood from Fingertip or Forearm Hematocrit Hct 30 55 Power CR2032 Lithium Cell 3V 2 ct Battery Life Over 2 000 Tests Display Dimensi...

Page 6: ...ace of the glucose meter including the test strip port and USB port after each use Be careful to make sure no liquid goes into either port Wipe the meter thoroughly the treated surface must remain vis...

Page 7: ...is in fault D Test result Shows the test result E Thermometer The themometer icon appears when the temperature is too high or too low F Application of blood or control solution Test your level of blo...

Page 8: ...at step 2 to set the date and time The flashing field is the one you are currently setting A AM P PM Setting the Time Date and Sound Volume First Time Use Setting the current time and date in your met...

Page 9: ...the test strip The strip will sip in the control solution Page 7 2 Place the meter on a flat surface Take the control solution between your fingertips and roll the solution back and forth to mix up th...

Page 10: ...Replace with new control solution to check the performance of the system Were test strips and control solutions stored in cool dry places Repeat the control test with properly stored strips and or co...

Page 11: ...the tip of the transparent window of the test strip Do not put blood on top of the strip Be sure to get enough blood on the strip s reaction zone Otherwise an inaccurate reading may result 6 The mete...

Page 12: ...F 1040 F 100 C 400 C This alerts users that an incorrect result may occur if the test continues Action Relocate the meter to a location with temperature between 500 F 1040 F 100 C 400 C The LF and the...

Page 13: ...EasyMax L Self Monitoring Blood Glucose System Training Information for Healthcare Professionals Page 11...

Page 14: ...of test strip Identifies the designated hand hold area 4 Demonstrates proper test strip use Only uses EasyMax blood glucose meters with EasyMax blood glucose test strips Runs a control solution test...

Page 15: ...ts are abnormally high or low 6 Quality Control Performs a control solution test and can explain why it should be done Understands the dates listed on the control solution and how they apply to opened...

Page 16: ...lower or higher than expected D All of the Above 4 When performing a blood glucose test where should you apply the blood A On top of the test strip B On the side of the test strip C The tip of the tes...

Page 17: ...dL 11 What type of battery does the EasyMax L require A 3 Volt Lithium B Alkaline 1 5 Volt AAA C Alkaline 1 5 Volt AAAA D None of the above 12 Describe the proper way to dispose of a safety lancet 13...

Page 18: ...ty Control Results Log Facility Name Monitor Month Year Results Reviewed by Date Time Staff Performing Test Strip Lot Low Control Normal Control High Control Action Taken Lot Range Result Lot Range Re...

Reviews: