Digital multimeter
ENGLISH
ENG
ENG
See
the
full
instruction
manual:
Features and components
•
The
KPS-MT720
is
a
portable,
hand-held
yet
professional
meter
that
features
an
LCD
with
backlight,
overload
protection
and
low
battery
indicator.
These
meters
are
easy
to
use
with
one
hand,
suitable
for
professional
users
or
amateurs,
and
ideal
for
school
or
home
use.
•
Functions
include:
AC/DC
voltage,
AC/DC
current,
resistance,
capacitance,
continuity,
diode
test,
frequency
and
duty
cycle.
•
Auto
and
manual
range.
•
Auto
power
off
•
Max
measurement.
•
Min
measurement.
•
Relative
measurement
•
Reading
Hold
function.
•
True
RMS.
•
Simultaneously
display
frequency
during
AC
voltage/current
measurements.
•
Non-contact
voltage
test.
Safety Information
WARNING
To
reduce
the
risk
of
electrical
shock,
product
damage
or
personal
injury,
please
fallow
the
safety
instructions
described
in
the
user
manual.
read
the
user
manual
before
using
the
meter.
This
instrument
meets
EN
61010-1,
EN
61010-2-030,
EN
61010-2-033
standards
for
safety
requirements
for
electronic
testing
instruments,
pollution
degree
2
and
over
voltage
rating
of
CAT
III
1000V
and
CAT
IV
600V.
Follow
all
safety
instruments
to
ensure
use
of
the
instrument.
Proper
use
and
protection
of
the
meter
will
ensure
long
lift
of
the
meter.
If
the
equipment
is
used
in
a
manner
not
specifie
by
the
manufacturer,
the
protection
provided
by
the
equipment
may
be
impaired.
Preparation
•
When
using
the
meter,
fallow
the
fallowing
safety
rules:
- Always
take
precaution
to
prevent
electrical
shock
- Never
misuse
the
instrument
•
Check
to
see
if
the
meter
or
any
components
were
damaged
during
shipment.
•
Check
the
meter
and
accessories
thoroughly
before
using.
•
Inspect
test
leads
and
probes
far
cracks,
breaks
or
crazes
on
the
insulation
befare
using
the
meter.
•
Use
test
leads
provided
with
the
unit.lf
necessary,
replace
test
leads
with
identical
specifications
Use
•
Turn
the
rotary
switch
to
the
required
function
and
range
to
be
measured.
•
When
using
the
CAT
IV
environment,
if
the
measuring
voltage
between
terminals
and
earth
ground
exceeds
600V,
CAT
111
environments
or
voltage
measurement
between
the
terminal
and
the
earth
more
than
1
OOOV,
do
not
measure
voltage.
•
Always
be
careful
when
working
with
voltages
above
60V
OC
or
30V
AC
RMS.
Keep
finger
behind
the
probe
barriers
while
measuring.Never
touch
probes
during
measurement.
•
Choose
the
highest
range
when
the
value
to
be
measured
is
unknown.
•
Remove
test
leads
befare
switching
functions
on
•
the
rotary
switch.
Do
not
perform
resistance,
capacitance,
diode
and
continuity
measurements
on
powered
circuits.
•
Never
connect
the
test
leads
across
a
voltage
source
while
the
rotary
switch
is
in
the
resistance,
diode
or
continuity
mode.
Doing
so
can
damage
the
meter.
•
Power
off
the
circuit
and
discharge
capacitors
before
testing
capacitance.
•
Do
not
place
the
meter
in
any
environment
with
high
pressure,
high
temperature,
dust,
explosive
gas
or
vapor.
•
Stop
using
the
meter
if
any
failure
or
abnormal
function
is
observed.
•
Do
not
use
meter
unless
battery
cover
is
in
place
a
secured.
•
Avoid
direct
sunlight,
exposing
batteries
to
humidity,
any
strong
magnetic
field
or
high
•
temperatures
to
ensure
the
extended
life
of
the
meter.
Maintenance
•
To
avoid
electric
shock
or
personal
injury,
repairs
or
servicing
not
covered
in
this
manual
should
be
performed
only
by
qualifie
personnel.
•
Remove
test
leads
befare
opening
battery
cover
•
To
avoid
incorrect
readings
causing
electric
shock
or
personal
injury,
when
low
battery
symbol
“
”
appears,
replace
batteries
immediately.
•
The
meter
can
be
cleaned
with
a
soft
cloth
to
remove
any
oil,
grease
or
grime.
Do
not
use
liquid
solvent
or
detergent.
•
When
the
instrument
is
not
in
use,
turn
rotary
switch
to
“OFF”
•
lf
the
instrument
is
not
to
be
used
for
an
extended
period
of
time,
remove
the
batteries
to
prevent
damage
to
the
instrument.
Replace Battery
WARNING
To
avoid
electrical
shock,
damage
or
personal
injury,
remove
test
leads
befare
opening
battery
cover.
•
lf
the
low
battery
symbol
”
”
appears,
the
battery
needs
to
be
changed.
•
Unscrew
the
battery
cover
from
the
back
of
the
meter
and
remove
the
old
battery.
•
lnsert
a
new
battery
and
replace
the
cover
and
tighten
it
to
the
meter.
Note:
Be
sure
to
note
the
battery
polarity
when
replacing.
Replacing Test Leads
Replace
test
leads
if
leads
become
damaged
or
worn.
WARNING
Use
meet
EN
61010-031
standard,
rated
CAT
III
1000V,
or
better
test
leads.
Accessories
Test
Leads
1
pair
Summary
instruction
manual
1
pc
Battery
9V
6F22
1
pc
Multifunctional
test
socket
1
pc
Electromagnetic
pendant
1
pc
K-type
temperature
probe
1
pc
ENGLISH
MGL EUMAN,
S.L.
Parque Empresarial de Argame,
C/Picu Castiellu, Parcelas i-1 a i-
4
E-33163 Argame, Morcí
n
Asturias, España, (Spain)
Tel.: +506 2280-1686 • Fax: +506
[email protected] • www.eproteca.com