SPEAKER CONNECTIONS
Use 14 or 16 gauge stranded two-conductor speaker wire. Connect the appropriate conductor
to each screw terminal, observing correct polarity.
CONTROL CONNECTIONS
IR
Connect a control system to this input via a mono connector (Signal and GND only, no 12V
signal supplied) to control the amplifier via IR from your control system. See page 6 for IR
port location.
Tip
Signal
Sleeve
Ground
RS-232
Connect using the correct pin configuration for the control system in use. Configuration for
control system serial ports can vary. Refer to the documentation for the system in use to
ensure proper connection and configuration.
TheESA-70V2CH-IP receives control data on pin 2 (RxD – Data Receive) and transmits control
data on pin 3 (TxD-Data Transmit). See the diagram below for details.
Pin
Function
2
RxD (Data Receive)
3
TxD (Data Transmit)
5
Ground/Common
IP
1.
Connect a Cat5e/6 network cable from the Ethernet port of the amplifier to a network
with DHCP enabled (DHCP server is usually in the router).
2.
Use an IP scanner to detect the IP address assigned to the amplifier.
3.
Enter the IP address into a web browser to access the user interface and change
settings.
Default Login Information:
• Username: admin
• Password: admin
The following settings can be changed in the web GUI:
• System Status
• Power On settings
• Input/Output configuration
• Network IP and Clock settings
• Audio Routing configuration
• Password settings
Sleeve
Tip
5
3 2
DB9 Female Connector
RxD (Data Receiver
TxD (Data Transmit)
GND