9
When the controller operates under
“
Condition 1
”or“
Condition 2
”, it will carry out the
charging as per the actual current or power; at this time, the controller can work at the
maximum power point of PV array.
WARNING:
When the power of PV is not greater than the rated charging
power, but the maximum open-circuit voltage of PV array is more than
50(Tracer**06AN)/96V(Tracer**10AN) (at the lowest environmental
temperature), the controller may be damaged.
Condition 3:
Actual charging power of PV array
>
Rated charging power of controller
Condition 4:
Actual charging current of PV array
>
Rated charging current of controller
When the controller operates under
“
Condition 3
”or“
Condition 4
”
,
it will carry out the
charging as per the rated current or power.
WARNING:
When the power of PV module is greater than the rated
charging power, and the maximum open-circuit voltage of PV array is more
than 50(Tracer**06AN)/96V(Tracer**10AN)(at the lowest environmental
temperature), the controller may be damaged.
According to “Peak Sun Hours diagram”, if the power of PV array exceeds the rated
charging power of controller, then the charging time as per the rated power will be
prolonged, so that more energy can be obtained for charging the battery. However, in
the practical application, the maximum power of PV array shall be not greater than 1.5
x the rated charging power of controller. If the maximum power of PV array exceeds
the rated charging power of controller too much, it will not only cause the waste of PV
modules, but also increase the open-circuit voltage of PV array due to the influence of
environmental temperature, which may make the probability of damage to the
controller rise. Therefore, it is very important to configure the system reasonably. For
the recommended maximum power of PV array for this controller, please refer to the
table below:
Model
Rated Charge
Current
Rated Charge
Power
Max. PV Array
Power
Max. PV open
circuit voltage
Tracer1206AN
10A
130W/12V
260W/24V
195W/12V
390W/24V
46V
①
60V
②
Tracer2206AN
20A
260W/12V
520W/24V
390W/12V
780W/24V
Tracer1210AN
10A
130W/12V
260W/24V
195W/12V
390W/24V
92V
①
100V
②
Tracer2210AN
20A
260W/12V
520W/24V
390W/12V
780W/24V
Tracer3210AN
30A
390W/12V
780W/24V
580W/12V
1170W/24V
Tracer4210AN
40A
520W/12V
1040W/24V
780W/12V
1560W/24V
①
At 25
℃
environment temperature
Summary of Contents for Tracer1206AN
Page 2: ......
Page 26: ...22...
Page 38: ...34 Annex II Dimensions Tracer1206 1210AN Unit mm...
Page 39: ...35 Tracer2206AN 2210AN Unit mm...
Page 40: ...36 Tracer3210AN Unit mm...
Page 41: ...37 Tracer4210AN Unit mm Any changes without prior notice Version number 1 0...
Page 42: ......
Page 43: ......