26
Control Parameter
There are 9 interfaces for
‗Control Parameter‘ as shown below.
Batt Type
SEALED
Batt AH
200AH
Over Volt. Disc.
16.0V
Charge Limit
15.0V
Temp Coefficient
-3mV
/
℃
/
2V
Rated Volt
AUTO
Over Volt. Rect
15.0V
Equalize Charge
14.6V
Boost Charge
14.4V
Float Charge
13.8V
Boost Rect Volt
13.2V
Low Volt Rect
12.6V
Under Volt Rect
12.2V
Under Volt Warn
12.0V
Low Volt Disc
11.1V
Discharge Limit
10.6V
Equalize Time
120 min
Boost Time
120 min
You should input the user password (see above) before setting the parameters.
In setting mode, all the parameters can be modified. And will immediately
effect when saved. The detail and value range of control parameter are shown
in the tables below:
Battery Charging Setting
Battery Type
Note
Sealed (Default)
Constant value
GEL
Constant value
Flooded
Constant value
User
Defined by user
Others
Parameter
Default value
Range
Battery capacity
200Ah
1~9999Ah
Temperature compensate
coefficient
-3mV/ºC/2V
-9~0 mV/ºC/2V
Rated system voltage
Auto
12/24/36/48VDC Auto