NOTE:
Load short circuit protection and the reversed polarity
connection will trigger automatically.
WARNING:
Controller will be damaged when the PV array
reverse polarity and the actual operation power of the PV array is
1.5 times greater than the rated charge power!
2.5 Power Up
CAUTION:
The controller is only powered by battery, so it will not
work when connected only to solar input.
WARNING:
Disconnect the battery will produce interference to
the load when the controller is work at charging.
WARNING:
Don‘t do the battery reversed polarity test within 10
minutes after power off.
REMARQUE :
Le contrôleur n'est alimenté que par la batterie,
donc il ne fonctionnera que lorsque branché sur l'alimentation
solaire.
AVERTISSEMENT :
La déconnexion de la batterie causera des
interférences sur le chargement lorsque le contrôleur fonctionne
et est en chargement.
AVERTISSEMENT :
N'effectuez pas le test de polarité inversée
de la batterie pendant 10 minutes suivant l'extinction.
Before switching on, recheck the step of
①~④
and make sure all wirings
correct, especially
④
connected with battery ,load and PV array.
Turn on the battery Fuse firstly. Observe if battery indicator light and
startup interface work fine or not (Refer to section 4). Always connect the
battery firstly, in order to allow the controller to recognize the system
voltage.
After battery works fine with power on, switch on the breaker of PV array.
With enough sunlight, the charging LED will blink and the controller will
begin charging.
If the battery LED error exists or LCD interface alarms, refer to section 5 for
troubleshooting. When disconnecting the system, the order will be
reserved.