32
CAUTION
When the overload protection happens, the AC output cannot recover automatically.
The AC output is shut down according to the multiple of the overload. Recover the
AC output after clearing the overload faults and restarting the inverter.
4) Output short circuit protection
Faults
Instruction
The output is switched OFF
immediately.
Buzzer beeps.
Red indicators fast flashes.
LCD displays the
.
Note: The AC output is recovered automatically three times
(recover after 5s, 10s, 15s separately). After the recovery
attempt failed three times, you need to restart the inverter to
recover the AC output.
5) Inverter over temperature protection
Faults
Instruction
LCD displays the
.
The inverter stops working.
The inverter stops working after the heat sink's temperature, or
the internal modules' temperature exceeds a set value.
The inverter resumes work.
The inverter works after the temperature of the heat sink or the
internal modules' temperature is lower than a set value.