Low voltage reconnect
voltage
③
12V: 12.5V
24V: 25V
48V: 50V
12V: 11.5V~15.2V; step size 0.1V
24V: 22V-31.2V; step size 0.1V
48V: 43V-63.4V; step size 0.1V
Over voltage
reconnect voltage
③
12V: 14.5V
24V: 29V
48V: 58V
12V: 11.5V~15.2V; step size 0.1V
24V: 22V-31.2V; step size 0.1V
48V: 43V-63.4V; step size 0.1V
Over voltage
disconnect voltage
③
12V: 16V
24V: 32V
48V: 64V
12V: 12.5V~16.2V; step size 0.1V
24V: 23V-32.2V; step size 0.1V
48V: 44V-64.4V; step size 0.1V
①
After configuring the parameters marked with
①
, the inverter will restart automatically. It will
resume work according to the new parameter value.
②
Due to the length limit of the LCD displayed data, when the baud rate is set to 115200, the value
displayed on the LCD is 1152.
③
For the parameter user defines, please refer to the input voltage rules in chapter 7
Otherwise, the parameter setting will not succeed.
5.4 Error code
Error code
Faults
Buzzer
Power
indicator
Fault indicator
Inverter over temperature
Heat sink over temperature
Buzzer
beeps
OFF
ON solid
Input over voltage
Buzzer
beeps
Fast
flashing
(1Hz)
OFF
Input low voltage
Buzzer
beeps
Slowly
flashing
(1/4Hz)
OFF
Output short circuit
Buzzer
beeps
OFF
Fast flashing
(1Hz)
Output overload
Buzzer
beeps
ON solid
Slowly flashing
(1/4Hz)