background image

                                         

BEIJING EPSOLAR TECHNOLOGY CO.,LTD. 

3

 

2. Exterior

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Controller case 

 

Battery terminals 

 

Mounting hole size

φ 4.5mm 

 

PV terminals 

 

SET

 

button 

 

Remote temperature sensor port

 

 

LCD   

 

RS485

 

communication port 

 

MENU

 

button 

 

Remote battery voltage sensor port

 

(1)

The  controller  will  charge  the  battery  at  25

  as  default  and  no  temperature 

compensation when the temperature sensor is damaged. 

(2) 

The  port  can  detect  accurate  battery  voltage(a  2P/1.5mm

2

  wire  (Red+,  black-) 

with insulation protection is suggested). One end connects the 5.08-2P terminal to 
insert 

  port,  the  other  end  connects 

the  battery,  and  make  sure  the  “+”  and  “-” 

poles are connected correctly. 

2.1 Designations of models 

 
 

 

 

Summary of Contents for GM3024N

Page 1: ...GoMate Series Flush Mount Solar Charger User Manual Model GM3024N...

Page 2: ......

Page 3: ...2 1 Designations of models 3 2 2 Accessories Included 4 2 3 Accessories Optional 4 3 Installation and wiring 5 3 1 Install the controller 5 3 2 Wiring 6 4 LCD display 8 5 Protection 10 6 Troubleshooti...

Page 4: ...ngs carefully before installation No user serviceable component inside the controller DO NOT disassemble or attempt to repair the controller Avoid direct sunlight high temperatures and DO NOT install...

Page 5: ...edded installation design High quality and low failure rate components ST IR to ensure the product lifetime 3 Stage intelligent PWM charging Bulk Boost Equalize and Float Battery type Sealed Gel Flood...

Page 6: ...e sensor port 1 The controller will charge the battery at 25 as default and no temperature compensation when the temperature sensor is damaged 2 The port can detect accurate battery voltage a 2P 1 5mm...

Page 7: ...on PC software The length of cable is 1 5m TheCC USB RS485 150U connects to the RS485 Port on the controller After the controller is connected with the eBox WIFI 01 through the standard Ethernet cable...

Page 8: ...ion of installation location The controller shall be installed in a place with sufficient air flow through the radiators of the controller and a minimum clearance of 150 mm from the upper and lower ed...

Page 9: ...ntroller 6 Install the control case 3 2 Wiring Step1 connect the battery CAUTION A fuse which current is 1 25 to 2 times the rated current of the controller must be installed on the battery side with...

Page 10: ...onable arrester in the PV array input side Step3 Connect the Remote temperature sensor cable NOTE The controller will charge or discharge the battery at 25 as default and no temperature compensation w...

Page 11: ...he SET button and hold 5s under the PV power interface and the value is flashing Step 2 Press the SET button to clear the generated energy 3 Switch the battery temperature unit Press the SET button an...

Page 12: ...ware www epever com Solar Station Monitor www epever com ChargeController Sealed 1 Only Sealed Gel and Flooded via the LCD The battery type of User can be set via the PC software APP software and MT50...

Page 13: ...ttery reverse polarity no damage will occur to the battery Correct the wiring error to resume normal operation Battery Overvoltage When the battery voltage reaches the overvoltage disconnect voltage i...

Page 14: ...PV array disconnection Confirm that PV wire connections are correct and tight LCD is no display Min 8V will start up the controller Measure battery voltage with multi meter Min 8V can start up the con...

Page 15: ...ate Coefficient 3mV 2V Default Charge Circuit Voltage Drop 0 21V The battery type of User can be set via the PC software APP software and MT50 Refer to table 1 Page 13 Environmental Parameters Storage...

Page 16: ...V Discharging Limit Voltage 10 6V 10 6V 10 6V 9 17V Equalize Duration 120min 120min 0 180min Boost Duration 120min 120min 120min 10 180min 1 When the battery type is sealed gel flooded the adjusting r...

Page 17: ...e environment PV or load current voltage or power exceeding the rated value of the controller The controller working temperature exceeds the range of working temperature User disassembles and attempts...

Page 18: ...BEIJING EPSOLAR TECHNOLOGY CO LTD 15 9 Dimensions Any changes without prior notice V1 1...

Page 19: ......

Page 20: ...BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 86 10 82894896 82894112 Fax 86 10 82894882 E mail info epsolarpv com Website www epever com...