2 Main function introduction

2.1 SF6200MA Function feature

Built-in 500W amplifier, integrated 8 power A + B independent dual speaker loop partition
output, each partition has a LED indicator, independent volume adjustment (6 files),
forcibly cut to output power 100V when receive alarm signal.

Partition output with three-wire, four-wire Strong cut regulation function.

With amplifier monitoring function.

With 4 audio input, 2 microphone input with 24V phantom power

Integrated independent EVAC voice information player. Voice files can be customized by
users

Built- in HD audio module, support to record real-time PPT voice during fire alarm.

Support TCP / IP communication protocol, after connecting to internet, all equipment in the
system can be operated in real time through PC client-side, and the state automatically
synchronized.

Extensible to more 19 Extension Controller and 32 remote microphones ( allow to change the
priority level)

2 channel of remote MIC online interface with 24 V power, using standard RJ-45 network
port and CAT-5 network cable, achieving lone-distance transmission.

Function of fault self-checking of the electrical system,and complete inspection of manual
system.

Measuring function of the status of each partition speaker loop(open circuit, short circuit,
overcurrent, impedance change).

With system failure, emergency dry node output, emergency reset dry node input.

The real-time indication function of the system status.

8- ways short circuit/level trigger manner, 3-way different audio sources to configure the
trigger response, output can be configured with arbitrary partition

group and Short circuit

contact combination.

External connecting a backup power amplifier, when the built-in amplifier doesn’t work, it
will switch to the backup amplifier automatically.

External 24V stand-by power supply, realizing continuous work without delay when power
off.

Built-in 24V automatic charging function

With one way IP address reset port.

Summary of Contents for SF6200MA

Page 1: ...ANUAL VOICE EVACUATION PUBLIC ADDRESS SYSTEM SF6200MA SF6200MS Thanks for using EPCOM Voice Evacuation Public Address System For better operation please read this manual carefully before operating the...

Page 2: ...1 Electrical Specifications 6 3 2 Performance Specifications 6 4 Device function description 11 4 1 Front panel function description 11 4 2 Rear panel function description 12 5 Operation Instructions...

Page 3: ...3 1 Product renderings 1 1 SF6200MA Product design sketch 2U FIGURE 1 1 SF6200MAProduct renderings 1 2 SF6200MS Product design sketch 2U FIGURE 1 2 SF6200MSProduct renderings...

Page 4: ...32 remote microphones allow to change the priority level 2 channel of remote MIC online interface with 24 V power using standard RJ 45 network port and CAT 5 network cable achieving lone distance tra...

Page 5: ...status of each partition speaker loop open circuit short circuit overcurrent impedance change The real time indication function of the system status 8 ways short circuit level trigger manner 3 way di...

Page 6: ...200Hz 10kHz Input impedance 1k Signal to noise ratio 70dB Unbalanced audio input Sensitivity of 350mV Frequency response 80Hz 16kHz Impedance 10k Signal to noise ratio 70dB Balanced line input Sensiti...

Page 7: ...MIC console CAN interface Baud rate of 38400bps Supports up to 20 remote MIC consoles Trigger input Short circuit mode short circuit Mechanical indicators Size L W H 484 350 88 mm 19 wide 2U Net weigh...

Page 8: ...thout configuration for DC power PAGING remote control microphone indicator green light means that the remote control microphone is paging the zone from the host SYS FAULT orange indicates the host is...

Page 9: ...volume adjustment knob 4 2 Rear panel function description Figure 4 2 SF6200MArear panel design sketch ON for power on OFF for power off DC POWER 24V DC input interface pay attention to positive and...

Page 10: ...l output a short circuit signal Emergency Rest Input when short circuit signal is input the fire alarm emergency status will be reset IMPEDANCE The button of impedance Calibration when it is pressed t...

Page 11: ...rgency function 1 Emergency voice function 1 Manually press the EMERGENCY button red light flashes 2 Press alert msg button on host panel to play alert voice language information the response is decid...

Page 12: ...en LINE7 indicator turn on means select MP3 1 Sound source play of each zone a The current selected audio source for MP3 turn on according zone can play MP3 sound source press all zone button all zone...

Page 13: ...m detection power 500W Installation of the new device requires sampling the speaker impedance the specific operation is as follows 1 Install new equipment connect speakers for each zone 2 Press impeda...

Page 14: ...ance 25 change detection sampling 30W speaker impedance plus or minus 7W press system fault self test button on the front panel the indicate light is orange and computer status is fault Then connected...

Page 15: ...ton to turn on or off the monitor Light on means amplifier monitor is turn on light off means amplifier monitor is turn off 5 7 IP address Reset Press the IP reset button to reset the host IP address...

Page 16: ...tch Settings Voice Evacuation Controller Address 1 2 3 4 5 6 7 8 1 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 2 1 1 0 0 0 0 0 0 3 0 0 1 0 0 0 0 0 4 1 0 1 0 0 0 0 0 5 0 1 1 0 0 0 0 0 6 1 1 1 0 0 0 0 0 7 0 0 0 1 0...

Page 17: ...20 0 0 1 1 0 0 0 0 12 1 0 1 1 0 0 0 0 13 1 1 1 0 0 0 0 14 1 1 1 1 0 0 0 0 15 0 0 0 0 1 0 0 0 16 1 0 0 0 1 0 0 0 17 0 1 0 0 1 0 0 0 18 1 1 0 0 1 0 0 0 19...

Page 18: ...Version 0 1...

Reviews: