Note: The characteristics may vary depending on the model of the equipment
Installation and initial ignition
Connect to a wall outlet
Plug the AC power cord of the UPS into the socket (110 Vac) of the wall. For best results, keep connected and operating for 8 hours before your initial application, in order
to charge the battery.
Connecting devices
With the device turned off, connect the loads or electronic equipment to the back of the UPS, then turn it on with the ON / OFF button. The equipment will be protected and
backed up in the event of a power failure.
CAUTION:
Never connect the printer or scanner to the UPS to avoid damage to the UPS
· Connect the telephone line, modem or fax only to the RJ-11 / RJ-45 inputs.
· Connect a single line that comes from the modem or telephone to the input port of surge suppressor "IN" and with another cable connect the output "OUT" to the computer.
· Connect the communication cable interface in models with port USB/RS-232.
· It allows the UPS station to be independent in its function of turning on, off and monitoring.
· Connect the interface cable to their respective ports and install the program so that you can perform the UPS on and off times, as well as its monitoring
through the computer.
Unit power (ON/OFF)
Press and hold the ON button until the green LED stays on, repeat to turn OFF.
Activate the LCD screen by pressing the ON/OFF button for 3 seconds, repeat this process to turn off.
Power-on function without energizing
When the UPS is off and there is no power supply, it is possible to start the UPS to power the computer equipment.
Alarm function
When the electrical network fails, the battery is in charge of supplying the current to the computer equipment, by means of the inverter of the UPS and a sound will be heard every 6 seconds,
for a lapse of 40 seconds. When the battery is about to reach the lower operational limit, it will emit an alarm sound every 2 seconds.
When it reaches the lower limit, the inverter circuit of the UPS will protect the battery to prolong its useful life. Then, it will issue a constant alarm for a long period of time and the UPS will
shut down.
Conditions for its position and / or storage
Install the UPS in a dust-free area that has adequate ventilation at least 20 cm away
from any equipment or object to avoid interference. Take into account the operational
temperature and humidity parameters of the UPS.
NOTE: Before installing and connection, verify the equipment is not damaged.