DANGER!
Danger to life due to fire or explosion!
Despite careful construction, electrical devices can cause fires.
• Do not pull out the connector, when grid-connected inverter is working,
so as to avoid electric shock hazard.
• Do not immediately contact pin, when grid-connected inverter after
disconnection, there may be residual electricity,
5.5.2 AC connection
Step 1: Assembling AC cables to connector supplied. See “5.5.1 AC Output Wring”.
Step 2: Make sure that AC and DC circuit breaker are disconnected.
Step 3: Connect L, N to AC circuit breaker.
−
Plug AC connector to corresponding AC terminals.
−
Screw AC cables to AC circuit breaker.
Step 4: Connect PE to the ground.
Step 5: Connect AC circuit breaker to utility grid.
Step 6: Make sure that all AC cables are firmly installed.
NOTICE
Assignment of AC cables should be paid attention to, especially
“PE/GND” wire.
5.6 Connecting communication cable
5.6.1 Assembling the RS485 plug connector
Step 1: Make the communication cable through the waterproof ring, and then
connect the cables to the terminal.