The minor revision returned will be calculated from the formula:
#11.29
Mod 100 + 1.
Where “
#11.29
Mod 100” refers to the fractional value of Pr
11.29
, (the value after the
decimal point).
e.g. For a value of “1.09” in Pr
11.29
, the minor revision returned is 10.
Bits
b0
to
b6
are used to inform the configuration tool that the advanced EDS file is not
enabled and each bit will be set to 1.
If an advanced EDS file is used then the revision number is calculated as shown below.
Minor revision
The minor revision returned will be calculated from the formula:
#11.29
Mod 100 + 1.
Where “
#11.29
Mod 100” refers to the fractional value of Pr
11.29
, (the value after
the decimal point).
e.g. For a value of “1.09” in Pr
11.29
, the minor revision returned is 10.
Sub-version
The sub-version returned will be calculated from the formula:
#11.34
+ 1.
e.g. For a value of “1” in Pr
11.34
, the sub-version returned is 2.
Serial Number
Returns the least 3 significant bytes of the SM-Ethernet MAC address. The MAC
address is set during production, and cannot be changed. This value is also displayed in
Pr
MM.35
.
Table 6.23 Basic revision
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Minor Revision
0
127
10
(All bits set to 1)
Table 6.24 Advanced revision
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Sub-version
0
Minor Revision
Name:
SerialNumber
Class
0x01
Default
N/A
Instance
0x01
Data Type
UDINT
Attribute
0x06
Access
Get
This can be used to find the complete MAC address of the module by combining the
numbers with 00:0D:1E:xx.xx.xx. Where xx.xx.xx. is a value in Pr
MM.35
converted to
base 16 (HEX). e.g. If Pr
MM.35
contains the value of 1193046, this would give the
complete MAC address of 00 0D 1E 12 34 56.