5
EN
Specifications
Power supply:
230 V 1 N AC 50 Hz
Switching capacity:
3 kW resistive load (AC1 operation) with 16 A protection
Heating time limitation:
6 h / 12 h / unlimited (via jumper setting)
Temperature control range:
30°C to 50°C
Temperature sensor:
KTY type in metal housing Ø15 x 65 mm
Hysteresis:
adjustable range 1K to 5K
Display:
LCD display 65 x 37 mm, multi-line alphanumeric illuminat-
ed
Light control output:
230 V, max. 100 W load
Extractor fan output:
230 V, max. 100 W load
Essence dosing pump output:
230 V, max 100 W load
Protection class:
IPx4 as per EN 60529 water splash proof
Housing:
Plastic, for surface mounting or semi-recessed installation
Size (H x W x D):
220 x 250 x 67 mm (35 mm depth requirement by semi-re-
cessed installation)
Ambient temperature (operation):
-10°C to +40°C
Ambient temperature (storage):
-20°C bis +70°C
Applicable norms:
•
2014/35/EU
•
2014/30/EU
•
DIN EN 60335-1
•
DIN EN 60335-2-53
•
DIN EN 60335-2-98
•
DIN EN 60335-2-105
•
DIN EN 62233
Notice
Only fOr use with the steam generatOrs steamrOck Basic.