28
GB
Note!
Excessive voltage fluctuations can impact on
the function of the machine and lead to serious
damage to the electronic control system.
Connection
1
Mains cable with plug
2
Feed line / flake ice machine
3
Feed line / cooling
4
Drain / cooling
5
Drain
• Connect the supply and return lines in com-
pliance with the national and international
guidelines.
• Connect the water supply in compliance
with DIN EN 1717. Observe the technical data
for the water supply.
• Connect the power supply.
Note!
Do not interconnect but separately fit water
drains 4 and 5 to a floor drain. This prevents water
from the cooling system's return pipe from being
pressed into the drain of the condensate dish.
4
1
2
3
5
Before taking out ice for use, remove
the ice added to the ice tray during the
disinfection phase.
Fig. 8