Connecting the lines
4.4
Connecting the consumer lines
WARNING
Risk of electric shock
There is a risk of electric shock when connecting the cables if the
control unit is connected to the power supply.
Ensure that the control unit has no power.
Required tools:
Flathead screwdriver
The front cover must be removed for the following steps. See:
Connecting the heater
1
Connect the cable from the sauna heater to the four terminals (heater)
W
,
V
,
U
,
N
and
PE
.
Always connect the neutral conductor
N
of the sauna heater as well,
because in humidity mode, one phase is rerouted from the sauna
heater to the vaporiser. This results in an asymmetrical heating load
and power flows through the neutral conductor.
The switching output of the control unit for the sauna heater has a
max. of 10 kW resistive load. It can be expanded as needed by an
optional output controller (LSG) so that it is possible to connect
sauna heaters with an output greater than 10 kW.
N
V1 S1
L1 L2 L3 N
N
W V U N WB
FN FL LN LL
M A I N S
O V E N
V A P.
L S G
(PE)
WM