EOS Compact DC/HC - Installation and Operating Instructions
EN-51
Connecting the lines
Connecting the vaporiser – without water shortage detection
1
CAUTION! Fire hazard from overheating.
If a vaporiser without water shortage detection is connected, the system
displays no error message if there is insufficient water.
Connect the cable from the vaporiser to the two terminals (VAP.):
a)
Connect the neutral conductor (blue cable) to terminal
N
.
b)
Connect the black cable to terminal
WB
.
The switching output of the control unit for the vaporiser has a max.
of 3 kW resistive load. It can be expanded, as needed, by an optional
output controller (LSG).
You can connect more than one vaporiser.
Connecting the output controller (LSG)
1
Connect the LSG cable to the three terminals (LSG)
V1
,
N
and
S1
.
See the installation instructions for the corresponding LSG for
information about how to connect the other cables for the optional
LSG.