EN-44
Installation and Operating Instructions - EOS Compact DC/HC
EN
Connecting the lines
If a bench sensor is connected, plug both the bench sensor cable and
the multisensor cable into (
C
)
Bench Sens.
.
If Multisensor and Bench Sensor are connected simultaneously, the
control unit detects this automatically.
4
Plug the terminal plug into the circuit board again as assigned.
4.4
Connecting optional modules
The EOS Compact control unit has a jack for sauna bus cables, which can be
connected via the optional modules.
For the item number, see Add-on modules,
The front cover must be removed for the following steps. See:
Add-on modules
SBM remote
start
With the SMB remote start module, the sauna cabin can be
switched on and off remotely with a button.
SBM-HOT
With the SMB-HOT module, an intense heat-up phase of the
sauna heater can be triggered. The heat-up phase can be trig-
gered manually by pressing the button.
SBM-ECO
With the SBM-ECO module, the temperature of the sauna cabin
can be lowered to a preset minimum heat level. This makes it
possible to keep the sauna cabin warm at a low, energy-saving
temperature when it is not in use.
SBM-KNX
SBM-Mod
The KNX module and Modbus module are intended to be con-
nected to a building management system. They facilitate the
remote control of various functions for sauna heaters with or
without a vaporiser.
S T B
Multi Sens.
Bench Sens.
Oven Sens.
S-BUS
WS
BL
A B C