ROUGH IN
Determine Location of Shower Mixer
Wall depth: min 50mm – max 75mm from finished wall
surface to the back of body.
The mixer must be installed in the correct orientation
with the 2 inlets in the horizontal plane (hot / warm on
left) and outlet facing the top.
Where required, an appropriate backflow prevention
device should be installed before a shower hose,
according to the cross-connection hazard rating.
(E.g. in cases where a shower hose is installed over a
bath, the shower outlet is installed at a low height, or
a shower hose is long enough to reach the floor, bidet
or a WC pan.) Refer to AS3500.1 - Section 4.
installation instructions
50 min.
75 max.
COLD IN
HOT or WARM IN
COLD / MIXED /
WARM or HOT OUT
Grey (Off)
Blue (Cold)
Red / Yellow
(Hot / Warm)
In-Wall Body Component
1. Ensure plumbing lines are flushed prior to
installation as debris in cartridge will void warranty.
2. Secure the Shower Mixer Body to the internal
cavity within the wall. The Shower Mixer Body
can be fixed to a masonry wall or wall frame using
screws suitable for the fixing method. (Fixing
screws not supplied.)
When mounting Shower Mixer Body on the wall,
take note of the minimum and maximum wall
thickness and the dimensions shown so that the
nogging or recess is correctly positioned and takes
into account the thickness of the finished wall.
3. Purge hot and cold water lines, and connect
water supply pipework to the hot and cold inlets.
Connect the shower outlet to the riser leading to
shower rose / outlet.
50 min.
75 max.