enware LEVA Series Installation And Maintenance Instructions Manual Download Page 3

www.enware.com.au  

Call 1300 369 273  

 

dimensions

  85 

 

  107 max.  

  26  

  51  

  51 

 

G1/2" (BSP)

FEMALE OUTLET

  54 

 

G1/2" (BSP)

FEMALE INLET

G1/2" (BSP)

FEMALE INLET

   75  

FULL WARM

FULL COLD

CLOSED

IN-WALL

ADJUSTMENT

components

SHOWER MIXER BODY

FLANGE

SEQUENTIAL CARTRIDGE

180° RTC

COLOUR INDICATORS

LOCKNUT

SPLINE ADAPTOR

TOOTH WASHER

NYLON WASHER

M5x20 HANDLE S/S SCREW

LEVA SEQUENTIAL

80MM HANDLE

Summary of Contents for LEVA Series

Page 1: ...enware com au Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph 02 8536 4000 info enware com au LEV80308SQ I00226_Oct 19 LEVA 80mm SEQUENTIAL SHOWER MIXER Installation and Ma...

Page 2: ...ay be required to comply with maximum temperature and pressure requirements please note Enware Australia advises 1 Due to ongoing Research and Development specifications may change without notice 2 Co...

Page 3: ...OUTLET 54 G1 2 BSP FEMALE INLET G1 2 BSP FEMALE INLET 75 FULL WARM FULL COLD CLOSED IN WALL ADJUSTMENT components SHOWER MIXER BODY FLANGE SEQUENTIAL CARTRIDGE 180 RTC COLOUR INDICATORS LOCKNUT SPLINE...

Page 4: ...instructions 50 min 75 max COLD IN HOT or WARM IN COLD MIXED WARM or HOT OUT Grey Off Blue Cold Red Yellow Hot Warm In Wall Body Component 1 Ensure plumbing lines are flushed prior to installation as...

Page 5: ...ure place until fit off FIT OFF FLANGE AND HANDLE 1 After waterproofing and bathroom finishing trades are complete operate the mixer to ensure system is still functional 2 Seal any gaps between the wa...

Page 6: ...stays at maximum but now the water is mixed with more hot or warm water At WARM or HOT position handle pointing straight up it is at full temperature and flow supplied to the hot inlet of the mixer an...

Page 7: ...dle Seal in Cartridge is worn or damaged Pressure too high Replace Cartridge Install pressure reduction valve ensure it is under 500 kPa Water is not flowing from tap Water turned off Turn water on tr...