14
Call 1300 369 273
www.enware.com.au
servicing
1. Ensure water supply is turned off and the battery or transformer is
disconnected (except ENM6250)
2.
Remove chrome cover cap using a small flat head screwdriver to
lever off. If tap is set for mixing, rotate temperature handle fully anti-
clockwise and remove handle using an allen key to press securing
lug inwards.
IMAGE 30
3. Unwind Allen head screw using a 2.5mm Allen key, and remove
handle bracket from temperature adjustment spindle.
4. Remove securing grub screw at back of the tap using the 2.5mm Allen
key and carefully lift the Chromed tap body vertically off the hob mount.
IMAGE 31
Be careful not to lift too high as cables will still be connected.
5. Disconnect sensor cable from solenoid valve.
IMAGES 32 & 33
NOTE: for ENM6250 models battery is within tap body and
should be removed at this point and replaced immediately
after the intended operation is complete.
See Changing Battery
Instructions
Page 15
6. Perform required operation then proceed .
7. For ENM6250 models, connect sensor to battery, for other models,
connect the sensor cable to the solenoid valve and feed power cable
of the sensor through the tap hob mount.
The solenoid and sensor connectors are to be secured within the
grey plastic connector housing which is fixed to the solenoid. Check
that the connector housing is in a suitable position in relation to the
internal cavity of the tap body.
IMAGE 34
. It should be positioned
where it will not interfere with the internal components, approximately
the same distance from the solenoid valve as the porting pipe.
IMAGES 35
NOTE: The longer end of the connector housing faces
downwards.
8. Lower the tap body, taking care not to pinch the cables, until it locates
over the lug on the hob mount, and the grub screw hole in the tap
body aligns with the grub screw hole in the hob mount. Secure in
place using the grub screw and tighten with the 2.5mm Allen key.
Replace the temperature handle/chrome cover cap.
9. Connect tap to its power source either 6V battery or 12V mains power
transformer cable. Ensure the battery is connected in its correct
configuration with the white line on the cable connector aligning with
the moulded line in the battery casing or white line on the transformer
cable connector. See Installation Instructions on
Page 13 IMAGES 17
& 18
WARNING: Failure to align the connections correctly will
result in permanent damage to the sensor & void warranty
10.
Turn power and water supply on and test operation.
ACCESS TO COMPONENTS -
REMOVING INTERNALS OF TAP FOR SERVICING
NOTE: Take note of the process and orientation
of removing components will require the reverse
process for refitting.
IMAGE 30
IMAGE 31
IMAGE 32
IMAGE 33
Equal distances
IMAGE 35
IMAGE 34
Targe
t area
Equal distances