22
Call 1300 369 273
www.enware.com.au
SERVICE AND MAINTENANCE
STEP 1
To change the battery, the thermostatic valve must first be
closed and the face plate, spout and dress flange removed as
per Step 1A - 1D Annual maintenance procedure
SEE IMAGES 1A, 1B, 1C, 1D, on page 18.
STEP 2
Remove the battery from within the box by pulling the battery
casing vertically upward, and then disconnect it from sensor
cable.
STEP 3
Open the casing cover and change the battery. Use only 6V
Lithium 2CR5 battery (Enware Part ENMS204). Replace the
battery casing cover.
STEP 4
Connect the battery casing to the sensor, making sure the white
line on the sensor cable connector aligns with the moulded line
of the battery casing. SEE IMAGE 44
STEP 5
Check that the sensor is working.
When the battery is first connected, red LED should light up in
the sensor lens. Activate the sensor and check that the solenoid
clicks when the sensor is activated.
STEP 6
Re-install the battery into the box. Re-assemble the face plate,
dress flange and spout.
STEP 7
Open the thermostatic valve and restore the temperature setting.
Use the 3/8” Allen key to turn the temperature gear clockwise, and
adjust the temperature gear until the water from the outlet reaches
the desired temperature - see Setting the Outlet Temperature in
Commissioning section on page 17.
IMAGE 44
Caution: Failure
to align the
connectors
correctly will result in
damage to the sensor
circuitry and void
warranty.
CHANGING THE BATTERY
Enware Product Code:
ENMS204
- 6V Lithium 2CR5 Battery
ENMS205
- 6V Lithium 2CR5 Battery with casing
If the mixer fails to function and there is a RED light displayed within the sensor when trying to activate the
product, this means that the battery is low in voltage and needs to be replaced.
ALIGN WHITE STRIP WITH
MOULDED LINE ON
BATTERY CASE
Summary of Contents for AQUABLEND ESQX TOUCH FREE SERIES