5
AFTER INSTALLATION THE END USER SHOULD
KEEP THIS GUIDE FOR FUTURE REFERENCE
DO NOT
THROW AWAY
Wiring Diagrams
230V
SELV
220V - 240V
50/60Hz
Mains Supply
220V - 240V
50/60Hz
Mains Supply
Local
Isolator
Local
Isolator
SELV Power
Supply
Connector
Block
Connect the local isolator to the Mains as part of the fixed wiring.
Connect the N and L connectors of the fan power cable to the
local isolator.
The red 12V cable from the unit must be connected to the red cable
on the SELV power supply using the supplied terminal block. The
black 12V cable from the unit must be connected to the black cable
on the SELV power supply using the supplied terminal block.
+12V DC (Red)
0V DC (Black)