 Installation Instructions  

05

IMPORTANT

Be sure to have read and understood these 

instructions before beginning the installation 

process.

PRE-INSTALLATION CHECK LIST

Make sure that the unit can physically fit in to 

the desired location.
The energiSava 250 unit should be 

situated so that access for maintenance or 

replacement of parts is possible. Make the 

ductwork runs as short as possible. Having 

the most direct route and using as few 

bends as possible will reduce air resistance 

and improve the efficiency of the unit.

SAFETY AND RECOMMENDATIONS

• All wiring must comply with Building 

Regulations and the current I.E.E. Wiring 

Regulations (BS7671) or the equivalent 

standards  for  your  country.  The  final 

installation should be examined and tested 

by a qualified electrician.

• Precautions must be taken to avoid the 

back-flow of gases into the dwelling from 

the open flue of gas or other fuel-burning 

appliances.

• Make sure the mains supply complies with 

the rating label for voltage, frequency and 

phase.

• This appliance can be used by children 

aged from 8 years and above and 

persons with reduced physical, sensory or 

mental capabilities or lack of experience 

and knowledge if they have been given 

supervision or instruction concerning 

use of the appliance in a safe way and 

understand the hazards involved. Children 

shall not play with the appliance. Cleaning 

and user maintenance shall not be made 

by children without supervision.

Summary of Contents for energisava250

Page 1: ......

Page 2: ...operly i e for the life of the building If the unit is mishandled you might break it This invalidates the warranty And remember if you have any problems please call our dedicated Technical Team We are...

Page 3: ...athroom and en suite rooms and ducts this to a central unit This extracted air passes through a high efficiency counter flow heat exchanger before being ducted to the outside Fresh air is drawn into t...

Page 4: ...for the unit All wiring must be completed by a qualified electrician This appliance is suitable for 230V 50Hz single phase supply fused at 3 amps The appliance is supplied with a 4 core mains flexible...

Page 5: ...ifications Maximum Flow Rate 75 l s 270m3 h MAX Protection Class IPX2 Heat Exchanger Counter Flow Plastic Supply Filter Extract Filter G3 G3 Fans EC Electronically Commutated DC Spigot 125mm Electrica...

Page 6: ...ith Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country The final installation should be examined and tested by a qualified electrician Pr...

Page 7: ...r Bypass The summer bypass helps reduce the air temperature coming into the dwelling during the summer months It is an automatic function and operates when the supply air temperature to the property i...

Page 8: ...of the electrical power supply or unit a fused switched isolator must not be mounted above or closer than 1m to a cooker where it could be affected by excessive heat or moisture 4 Make sure that ther...

Page 9: ...sitioned so that there is enough space for the condensate drain and ducts to be connected Fixing kit provided 2 Attach spacers x 2 with screws provided The spacers ensure that the unit tilts forward t...

Page 10: ...ions SECOND FIX Airflow and drain fitting LH Drains are factory fitted The units has either a LH or RH drain To atmosphere From atmosphere Extract from dwelling Supply to dwelling To atmosphere From a...

Page 11: ...r KIT CONDENSATE ES250 2 Use the long and short S brackets provided along with short fitting screws to ensure correct drainage The unit must be higher at the duct end Drain connections should be solve...

Page 12: ...nt RH drain Drill into the bottom of the case as shown using the metal plate as a guide Ensure that the foam core is fully removed 20mm Saw To atmosphere Extract from dwelling From atmosphere Supply t...

Page 13: ...of the Building Regulations Open ceiling wall valves Measure all extract points summing the individual room rates Measurements to be carried out with an appropriate anemometer Adjust using and button...

Page 14: ...mmissioning to the next setting Sup B and so on When the unit has been fully commissioned press the SET button for 4 seconds and this will put the unit back into status mode If the unit is not put bac...

Page 15: ...ess the button once The functions currently in operation will be indicated with a lit LED If the filter light is on the filters will need checking see maintenance pages 16 17 Warnings All LEDs flashin...

Page 16: ...enough space left for servicing Condense drain is tight drains to a suitable location and has been water tested All major building works have been completed prior commissioning Supply and extract hav...

Page 17: ...uum the outside of the filter or replace if required 6 After cleaning replace filters at same side 7 Replace filter covers and front panel Clearing filter indication To clear the filter indication lig...

Page 18: ...ads 2 Remove retaining screws and washers x 4 store safely 3 Carefully remove the top foam moulding by pulling it straight forward Foam mouldings must remain parallel Take care not to damage the seali...

Page 19: ...ired and that any fans bought from an unapproved source including but not limited to Ebay will render the guarantee invalid Serial number of the unit We appreciate you choosing this quality EnviroVent...

Page 20: ...viroVent House Hornbeam Business Park Harrogate HG2 8PA 01423 810 810 info envirovent com www envirovent com Due to our policy of continuous innovation and improvement EnviroVent reserves the right to...

Reviews: