AFTER INSTALLATION THE END USER SHOULD 

KEEP THIS GUIDE FOR FUTURE REFERENCE

DO NOT THROW AWAY

energiSava® 250

CEILING MOUNTED VERSION
INSTALLATION GUIDE

Summary of Contents for energiSava 250

Page 1: ...AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY energiSava 250 CEILING MOUNTED VERSION INSTALLATION GUIDE...

Page 2: ...eparation of 3 0mm must be used to provide isolation for the unit The power cable running into the unit must remain the supplied flexible cable If the power cable becomes damaged it must be replaced b...

Page 3: ...must ensure the external supply grilles are positioned away from open flues to avoid drawing harmful gases into the property Consult your local regulations or a qualified gas engineer Users This unit...

Page 4: ...D YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL US ON Diagrams Overall unit dimensions and minimum area required for access maintenance mm The energiSava 250 spigots are compatible with 125mm d...

Page 5: ...ower cable to the matching terminals on the local isolator 3A fuse spur or similar The black switch live core of the mains cable can be wired to a switch input such as a light switch When the switch i...

Page 6: ...te heat energy from the extracted air to the supplied air in order to improve the indoor air quality of the property and reduce heating costs When outdoor temperatures are low the frost protection fea...

Page 7: ...nit condensate drain to the internal waste system of the property EnergiSava 250 1x energiSava 250 unit 1x Remote control 1x Instruction guide 1x User guide 2x Mounting brackets 10x Screws 8g x 2 0 10...

Page 8: ...u are satisfied with the position line up the two brackets using the printed template then secure them to the mounting surface Use 10 8gx2 0 screws and 10 plasterboard plugs 3 Mount the unit onto the...

Page 9: ...he MVHR unit and the supply and extract valves 5 6 7 Ductwork should be fitted in accordance with the Domestic Ventilation Compliance Guide Example RH unit configuration shown Ducts to and from atmosp...

Page 10: ...water system in the property A suitable non return device must be fitted to ensure air and waste water from the drain system do not flow back up into the unit The drainage must be fitted with a minim...

Page 11: ...and in accordance with the local wiring regulations When the power is turned on air will begin flowing into the property after a few seconds 10 11 If you are installing a remote switch RS unit a Open...

Page 12: ...other countries please refer to the relevant local Building Regulations for that country Determine the required ventilation rates For guidance see Approved Document F of the building regulations for E...

Page 13: ...sing the previous steps for adjusting air flow rates and valves When maximum speed setting is reached the LED will flash faster When the minimum speed setting is reached the LED will flash slowly Step...

Page 14: ...pple and Android devices A separate instruction guide for the myenvirovent app is included in the box The guide can also be accessed from within the app Once the unit has been installed refer to this...

Page 15: ...setting is 20 minutes then automatically return to trickle mode If the switch live connection is turned on then boost cannot be cancelled until the switch live connection is turned off To deactivate t...

Page 16: ...l the filter LED flashes green the filters need to be replaced Contact EnviroVent to order new filters After replacement filters have been installed wake the remote control Press and hold the button f...

Page 17: ...on 01423 810 810 for further help When the remote control battery needs to be replaced remove the two screws then open the remote control The battery is located on the back of the front cover Replace...

Page 18: ...80m3 h Maximum power consumption 150W Electrical Supply 230V Single Phase 50 60Hz Ingress protection rating IPX2 Filter grade ISO Coarse 45 G3 Boxed unit weight 16kg Unboxed unit weight 14kg Technical...

Page 19: ...lly fixed and sealed Both filters are inserted into the filter slots on the unit The unit is securely fixed with adequate space left for servicing Condensate drain is securely connected to the waste w...

Page 20: ...om the mains supply Remove the filter caps replace both filters then reinsert filter caps Engage the mains supply then reset the filter indication by pressing the minus button for 10 seconds The filte...

Page 21: ...lter FILTER ES250 125mm white supply valve 1DIFSUPPLY125WH 125mm white extract valve 1DIFEXTRACT125WH 150mm white supply valve 1DIFSUPPLY150WH 150mm white extract valve 1DIFEXTRACT150WH Spare remote c...

Page 22: ...n supplied and installed by EnviroVent Ltd it is covered with a two year parts and labour warranty If you detect a fault please contact us on 01423 810810 You will be given guidance over the phone or...

Page 23: ...ed repaired taken apart or tampered with by any person not authorized which in any way contradicts the instruction guide set out by EnviroVent The warranty does not cover accidental damage misuse or a...

Page 24: ...n and appearance without notice We want to hear from you Your feedback is important to us as we strive to improve our products services and overall customer experience Please email us to help us serve...