RKN e1 CONTAINER CHECKLIST
RKN e1 CONTAINER CHECKLIST
For Refrigerated and Controlled Room Temperature Products
Start the container by pressing the On/Off button without the container being connected to the mains.
The indicators on the display unit are lit to test functionality. If the container does not start, ensure the
container battery switch is on.
CONTAINER CHARGING
Connect container to AC power outlet to charge the batteries.
Ensure the blue charging light is lit (flashing or fixed).
CONTAINER PRECONDITIONING
(If preconditioning is performed with container running in non temperature-controlled area)
Perform a functional test of container.
Make sure container doors are properly closed.
Set container temperature to the desired set temperature.
Wait at least 30 minutes before loading cargo.
(If preconditioning is performed with a temperature-controlled room)
Perform a functional test of container.
Place the container in a temperature-controlled that is set to the desired temperature.
Make sure container doors are open.
Wait at least 1 hour before loading cargo.
CONTAINER LOADING
Ensure product, packing material & container is preconditioned prior to loading.
Minimize exposure of product to ambient temperatures during loading into the container.
Place cargo on pallet or spacers at least 2 cm (0,8 in) high, to ensure sufficient airflow between cargo and
floor.
Make sure no boxes are loaded in a way that blocks the airflow between the spacers inside container walls.
Secure the cargo using the container’s tie-down brackets.
Close and secure the container doors.
Check that no alerts are active.
Make sure the blue charging light is fixed (not flashing) before disconnecting from AC power.
Ensure all charging equipment is correctly stowed in the charging unit, and that all adapters are in place.
TRANSPORT / HANDLING / STORAGE
Charge container whenever possible.
Comply with specified limits and conditions.