background image

4.  A duct adapter and a length of 8 inch flexible hose 

or  duct  is  required  to  attach  between  the  8  inch 

intake  collar  and  the  existing  cold  air  return  duct.  

When  running  the  hose, make sure  that  there  are 

no  kinks  or  sharp  bends  that  will  impede  the  air 

flow  to  the  unit.    Secure  and  seal  the  hose  and 

connections to prevent air leakage. 

5.  A duct adapter and a length of 6 inch flexible hose 

or  duct  is  required  to  attach  between  the  exhaust 

collar and the existing cold air return. The exhaust 

hose  should  be  attached  to  the  return  air  duct, 

close  to  the  furnace.  The  ideal  location  is  low  on 

the  return  air  boot  pointing  at  the  furnace.  To 

prevent  air  shear  inside  the  duct,  it  is 

recommended that you install a deflector inside the 

boot,  so  the  discharged  air  is  deflected  down  into 

the  boot.  When  running  the  hose,  make  sure  that 

there are no kinks or sharp bends that will impede 

the  air  flow  from  the  unit.    Secure  and  seal  the 

hose and connections to prevent air leakage. 

6.  It is  important to maintain some distance between 

the  intake  and  the  exhaust  openings  in  the  return 

air  duct.  Failure  to  do  this  may  result  in  short 

cycling  between  the  intake  and  the  clean  air 

discharge.  It  is  recommended  you  leave  10  feet 

between  the  intake  and  the  exhaust;  however,  as 

little as 6 feet will work effectively. If the distance is 

smaller  than  6  feet,  it  is  important  that  an  air 

deflector is installed in the duct. 

7.  If  outside  air  is  introduced  into  the  return  air  duct, 

either through a HRV (Heat Recovery Ventilator) or 

direct, it should be added to the system before the 

intake inlet to the Air Cleaner.  

OPERATING INSTRUCTIONS

 

The HEPA Air Cleaner is designed to run continuously 

to provide clean, filtered air 24 hours a day. The fan on 

the  heating/cooling  system,  to  which  the  HEPA  Air 

Cleaner  is  dependent  on  for  circulated  air,  should  be 

on ‘continuous’. 

Note:    If the system fan setting is on ‘automatic’, it is 

recommended  the  HEPA  Air  Cleaner  be  operated 

through  an  air  switch  or  relay  to  turn  the  Air  Cleaner 

off, when there is no system fan on. 

The  unit  plugs  into  a  regular  120  volt  outlet  and  is 

controlled  by  a  switch  located  on  the  rear  panel,  near 

the cord. 

Note:  Do not allow the cord to be placed where it 

may be walked on or allow anything to roll over it. 

The  top  cover  must  be  secured  for  the  Air  Cleaner  to 

operate.    All  filters  must  be  in  place  for  the  unit  to 

operate properly. 

 

 

 

 

 

 

 

 

MAINTENANCE

 

For efficient operation, the filters must be changed on a 

regular basis. If you notice a reduction in air flow from 

the system, check the filters.  
1.  To  access  the  filters,  turn  the  Air  Cleaner 

OFF

  at 

the switch and remove the top cover. 

2.  Release  the  filter  hold  down  bar  by  pulling  it 

forward one side at a time. 

3.  Carefully remove filters to avoid spilling of collected 

contaminants.  Dispose  of  filters  in  a  plastic  bag 

and discard with regular household trash. 

4.  Remove  plastic  from  new  filters  before  installing. 

Discard plastic safely. Take care not to damage the 

filters. 

5.  Date the replacement filter in the space provided. 
6.  Place  the  Carbon  prefilter  around  the  HEPA  filter 

and secure with the Velcro. 

7.  Ensure  the  open  end  of  the  HEPA  filter  is  toward 

the motor. 

8.  Replace  the  filter  hold  down  bar  by  placing  one 

side  under  the  bracket  on  the  side  of  the  cabinet.  

Once  you  have  one  side  started,  force  the  bar 

under the bracket on the other side of the cabinet.  

This ensures the filter has a good seal. 

9.  Use  genuine  replacement  filters  only.  Call  the 

original installer for parts. 

Note:    When  the  filters  are  new,  you  may  notice  a 

new  smell  from  the  system.  This  is  normal  and  will 

dissipate within a few days. 
Carbon  Prefilter  (Part  #W3-0855):

    This  must  be 

replaced  every  3  -  6  months  and  may  be  vacuumed 

between  changes.  Use  a  soft  brush  attachment  when 

cleaning.    If  there  are  heavy  odors  in  the  home  from 

cooking,  smoking,  painting  or  other  sources,  the  filter 

will require changing more often. 

True HEPA Filter (Part #W3-0840):

  Replace every 2-

3 years. The life of this filter depends on the amount of 

contaminants in the air and the frequency in which the 

prefilter  has  been  changed.  Renovations  in  the  home 

that create wood, drywall dust or similar contaminants 

will  shorten  the  life  expectancy  of  the  HEPA  filter.  To 

improve  airflow,  the  HEPA  filter  can  be  vacuumed 

between  changes,  preferably  outdoors.  Use  a  soft 

brush attachment for vacuuming this filter. 

Note:    Handle  the  HEPA  filter  by  the  frame  only. 

The paper is fragile and a puncture or tear will reduce 

efficiency. 

VOC  After  Filter  (Part  #W3-0810  optional):

    This 

filter is  positioned inside the HEPA filter, and  must be 

replaced  every  6-12  months.  If  there  are  heavy  odors 

in  the  home  from  cooking,  smoking,  painting  or  other 

sources, the filter may require changing more often. 

 

WARNING  

Never use the unit without all of the filters in place.  

CAUTION  

Make  sure  to  turn  Air  Cleaner 

OFF

  before 

performing  any  maintenance  or  removing  any 

components.  