32
Installation
t
heRmoStat
i
nStaLLation
:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
Figure 46: Thermostat wire placement.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2
gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode, the unit
will be taken to a low or idle setting when the thermostat
is not calling for heat. When the thermostat calls for
heat, the unit will go to the setting that is displayed on
the control board Heat Indicator. If the heating load is
not great enough when the stove is on low, the high limit
switch will turn the stove off and the switch will have to
be manually reset. To reset the high limit switch, remove
the right cabinet side. The switch is found behind the
control panel. Avoid setting off the high limit switch.
*To achieve Maximum
efficiency of 75.1% HHV
you will need to purchase
meridian top vent adapter
kit. (50-4117)
Use the sheet metal screws
to attach the kit to the rear
of the unit. Please see
kit instruction manual for
more detailed installation
instructions.