10
g
uiDeLineS
f
oR
f
ine
-t
uning
f
oR
f
ueL
Q
uaLity
:
Due to fuel quality the slider damper and control board trims may need to be fine-tuned.
1. If the unit has excesses ash build-up in the liner on the lower feed settings, the Combustion Blower
Trim should be increased one setting at a time until the problem improves (Factory Setting is #2).
2. If the fire is going out on low because the airflow is too great, the Combustion Blower Trim can be
lowered to the #1 setting.
3. If the stove has excesses ash build-up in the liner on the higher settings the Feed Rate Trim should be
trimmed down a setting at a time until the problem improves (Factory setting is #4).
4. If you need more heat and the fuel has long pellets, the majority are over 1” (2.5cm) in length, the
Feed Rate Trim can be moved up to the #5 setting. NOTE: Only do this if the fuel burns without
building up.