13
Installation
C
LEARANCES
TO
C
OMBUSTIBLES
:
This unit can be installed on a combustible floor due to the built in pedestal hearth pad (for example
linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must
be used for stability.
A
LCOVE
C
LEARANCES
:
This unit may be installed in an alcove. Maintain
these clearances to combustibles.
Minimum Alcove width
48 inches (122 cm)
Minimum Alcove height
48 inches (122 cm)
Minimum Alcove depth
48 inches (122 cm)
Install vent at clearances specified by
the vent manufacturer.
��
�
�
�
��
�
���� ����
��
���
��
� �
���
��
������
��
�������
�� �������
48"
(122cm)
48"
(122cm)
48"
(122cm)
These dimensions are minimum clearances
but it is recommended that you ensure
sufficient room for serving, routine cleaning
and maintenance.
Side wall to unit 6 inches (15 cm)
Back wall to unit 3 inches (7.5 cm)
Corner to unit
3 inches (7.5 cm)
Figure 6: EF5 Clearance to Combustibles.
Figure 7: EF5 Minimum Alcove Size.