2

November 2011

Installation

Dimensions – Evolution EF5 Freestanding

Installation Clearances & Specifications

Minimum  clearances  shown  are  in  millimetres.    All  Enviro  fires  are  tested  to  AS/NZS2918:2001.  

Specifications were correct at time of printing but may alter and those detailed below should be used as 

a guide only.  Refer to the Installation and Operation Manual supplied with every Enviro Pellet Fire or if 

in doubt, consult your Switch Retailer.  Refer to Safety Test 09/1981 for all clearances to combustibles.

Clearances to Combustibles 

22 

1

/

4

"

(565 mm)

34 

5

/

16

"

(871 mm)

23 

7

/

16

"

(595 mm)

5

/

8

"

(144 mm)

26 

3

/

8

"

(670 mm)

28"

(711 mm)

24 

3

/

8

"

(619 mm)

B

J

H

A

E

External Flue

J

J

F

B

I

F

E

Enviro Evolution EF5 Pellet Fire

Clearance to Combustibles

B

C

A

E

D

G

F

B

F

G

E

Internal Flue

Location

Dimension 

(mm)

A

100

B

150

C*

50

D

~210

E

N/A

F

75

G*

50

H

100

I*

50

J*

25

Freestanding 

Clearances

* from shielded flue

Note:

 AS/NZS 2918 

requires a minimum 

of 100mm clearance 

for any side requiring  

access.

Note:

 These are 

minimum clearances to 

combustibles.  Actual 

installation distances 

may be greater.

Note: The above clearance to combustibles on the flue are only applicable within the fire envelope. Clearance outside this e.g.at a ceiling / wall thimble reverts to 25mm as per ARS flue 

test 05/1185.