background image

7

November 2011

Insert Flue Kit (52)

Each 52 Insert Flue Kit contains:-

y

ti

t

n

a

u

Q

n

o

i

t

p

i

r

c

s

e

D

o

N

 t

r

a

P

2

Stainless steel inner liner

ø75mm x 900mm long

5

8

Rain cap 75mm

1

12

T-adaptor/cleanout – ø75mm

1

16

Clamp – flexible flue to

stainless flue pipe

1

19

Flexible flue pipe – stainless

steel ø75mm x 1m

1

21

Bracket 75mm securing

flue pipe to wall

1

839

Casing cover – standard 

ø75mm - ø300mm

1

34

Chimney cover – may be required

as an optional extra

This flue kit may be used in replacement applications

in masonry chimneys. The overall height of the flue is

4.5m. Kit is supplied in two cartons. 

Note:

The Davin 52 Insert Flue Kit

complies with AS/NZS 2918:2001 as per
Applied Research Test Report 05/1185,
dated 15 September 2005. 
All fires must be installed by a qualified
installer as per the manufacturer’s
instructions and AS/NZS2918:2001.

Heat-resistant

floor protector

Seismic restraint chain.  To be fitted one on each

side of the fire at the mid point.  The chain should

have a breaking strength of at least 350kg or

minimum 3.5mm nominal diameter.  Chains

should be anchored to the floor (not framing or

masonry), and should be as short as possible,

only allowing access to unbolt the chains from the

fire to allow the fire to be pulled forward for servicing.

Chimney cover

– optional extra

150mm

(minimum)

Insert Flue Kit

52

To order :

December 2006

Telephone 0800 765 431.  Fax 64 3 341 8057            [email protected]  www.switchenergy.co.nz

Drawing representative only - not to scale.

Summary of Contents for EF2

Page 1: ...ing Models Installation Specifications Safety testing of the EF2 Classic FS CB Pellet Burning Heater to AS NZS 2918 ARS 09 1981 08 1902 Emissions 07 1731 Safety testing of the EF2 Classic FPI CB Pelle...

Page 2: ...2 November 2011 Installation Dimensions Classic Freestanding Dimensions Classic Insert Built In Heater 597 mm 525 mm 556 mm 767 mm FPI 612 mm 333 mm 559 mm FPI 579 mm...

Page 3: ...H A E J J F B I F E Location Dimension mm A 100 B 150 C 50 D 210 E N A F 75 G 50 H 100 I 50 J 25 Location Dimension mm K 100 L 920 M 1020 N 150 O 150 P 50 NOTE Built In fire clearances don t apply in...

Page 4: ...ted The Classic must be installed on a non combustible surface This surface must protrude 150mm from the front of the closed pellet fire door The Classic has been Safety Tested to AS NZS 2918 using th...

Page 5: ...ing plate is white T he support angles for securing the liner to the ceilin g are not shown Kit is supplied in a carton Heat resistant floor protector Seismic restraint to be fitted 50mm minimum clear...

Page 6: ...s supplied in a carton Note The Davin 51 External Standard Flue Kit complies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 All fires must be installed by a...

Page 7: ...ies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 All fires must be installed by a qualified installer as per the manufacturer s instructions and AS NZS2918...

Page 8: ...the flue is 3 6m Kit is supplied in a carton Note The Davin 54 Built in Heater Flue Kit non Chimney complies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 A...

Page 9: ...HVU Installation of the Insert Model non combusitble cavity requires the use of a seismic restraint chains to be fitted one on each of the fire at the mid point The chain should have a breaking stren...

Reviews: