background image

5

November 2011

Internal Standard Flue Kit (50)

Internal Standard Flue Kit

Each 50 Internal Standard Flue Kit contains:-

y

ti

t

n

a

u

Q

n

o

i

t

p

i

r

c

s

e

D

o

N

 t

r

a

P

1

Galvanised outer liner

ø100mm x 900mm long

1

4

3
2
1

1
1
1

1

1

2

2

Stainless steel inner liner

ø75mm x 900mm long

4a

Black p/coat outer liner

ø100mm x 900mm long

5

Inner/outer flue liner spacer

6c

Ceiling thimble ø107mm hole

7c

Ceiling decor plate

ø107mm hole – white

8

Rain cap 75mm

9

Rain Cap 100mm

10b

Elbow 45° – ø75mm stainless

– black  (painted)

12H 

T-adaptor/cleanout – ø75mm

– black  (painted)

23

Support angle 950mm long

– 50mm x 50mm sides

This  flue  kit  may  be  used  in  new  and  replacement

applications in rooms with stud height of 2.4m. The

overall height of the flue is 3.6m. The visible flu e is

finished  in  black  and  the  ceiling  plate  is  white.  T he

support angles for securing the liner to the ceilin g are

not shown. Kit is supplied in a carton.

Heat-resistant

floor protector

Seismic restraint

(to be fitted)

50mm minimum clearance if lined flue

600mm from

roof

penetration

~

210

 

mm 

150mm 

(minimum)

Note:

The Davin 50 Internal Standard Flue

Kit complies with AS/NZS 2918:2001 as per
Applied Research Test Report 05/1185, dated
15 September 2005. 
All fires must be installed by a qualified
installer as per the manufacturer’s
instructions and AS/NZS2918:2001.

50

To order :

Telephone 0800 765 431.  Fax 64 3 341 8057            [email protected]  www.switchenergy.co.nz

December 2006

Drawing representative only - not to scale.

This flue kit may be used in new and replacement 

applications in rooms with stud height of 2.4m.  

The overall height of the flue is 3.6m.  The visible 

flue  is  finished  in  black  and  the  ceiling  plate  is 

white.  The support angles for securing the liner to 

the ceiling are not shown.  Kit is supplied in carton.

Summary of Contents for EF2

Page 1: ...ing Models Installation Specifications Safety testing of the EF2 Classic FS CB Pellet Burning Heater to AS NZS 2918 ARS 09 1981 08 1902 Emissions 07 1731 Safety testing of the EF2 Classic FPI CB Pelle...

Page 2: ...2 November 2011 Installation Dimensions Classic Freestanding Dimensions Classic Insert Built In Heater 597 mm 525 mm 556 mm 767 mm FPI 612 mm 333 mm 559 mm FPI 579 mm...

Page 3: ...H A E J J F B I F E Location Dimension mm A 100 B 150 C 50 D 210 E N A F 75 G 50 H 100 I 50 J 25 Location Dimension mm K 100 L 920 M 1020 N 150 O 150 P 50 NOTE Built In fire clearances don t apply in...

Page 4: ...ted The Classic must be installed on a non combustible surface This surface must protrude 150mm from the front of the closed pellet fire door The Classic has been Safety Tested to AS NZS 2918 using th...

Page 5: ...ing plate is white T he support angles for securing the liner to the ceilin g are not shown Kit is supplied in a carton Heat resistant floor protector Seismic restraint to be fitted 50mm minimum clear...

Page 6: ...s supplied in a carton Note The Davin 51 External Standard Flue Kit complies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 All fires must be installed by a...

Page 7: ...ies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 All fires must be installed by a qualified installer as per the manufacturer s instructions and AS NZS2918...

Page 8: ...the flue is 3 6m Kit is supplied in a carton Note The Davin 54 Built in Heater Flue Kit non Chimney complies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 A...

Page 9: ...HVU Installation of the Insert Model non combusitble cavity requires the use of a seismic restraint chains to be fitted one on each of the fire at the mid point The chain should have a breaking stren...

Reviews: